Fire Rated Wall Panels · 200 mm
Fire Rated Wall Sandwich Panels — 200 mm
The 200 mm Fire Rated Wall Sandwich Panel is the deepest of the three fire-rated thicknesses Jawdah lists, and 200 mm is also the largest wall panel thickness in the Jawdah range.
- Thickness
- 200 mm (deepest listed)

Overview
Quick answer
Jawdah lists a 200 mm Fire Rated Wall Sandwich Panel, the deepest of its three fire-rated thicknesses. The supplied data states no fire class, no fire-resistance period, no core and no thermal values for it. Being the thickest option does not prove the longest fire performance; ask Jawdah for test evidence that names the 200 mm panel before you specify it.
Overview
What sets the 200 mm fire rated panel apart
Its supplied record holds the name and the depth; fire class, fire-resistance period and core material are not stated.
Because 200 mm is the thickest option, buyers sometimes assume it carries the highest fire performance. This page explains why that cannot be taken for granted, what a 200 mm wall means for handling and detailing, and what to ask Jawdah for. Fire terminology is covered on the Fire-Rated Wall Sandwich Panels page.
At 200 mm the panel is twice the depth of the 100 mm fire rated version and the thickest of the three. In Jawdah's wall range only the cold room panels reach the same depth. The panel follows the sandwich principle of two metal facings bonded to a core, made as one element in the factory and fixed to the building frame.
Depth is the one property the record confirms. The core behind the facings, the way the panel behaves when exposed to fire and any fire-resistance period of a wall built from it are not stated, so the 200 mm panel needs the same written evidence as its thinner siblings before it can answer a fire clause.
How it works
Thickest is not the same as longest-lasting in fire
A fire-resistance period is earned by a tested assembly, and the core material usually decides more than depth does. A deep panel with a combustible core can perform differently from a slimmer panel with a non-combustible one. For that reason the 200 mm figure tells a reviewer nothing about fire on its own.
Test evidence has its own limits too. A report on a 200 mm specimen states the joint, fixing and support conditions that were tested; walls built differently, or taller than the tested arrangement allows, need a separate check by the fire engineer.
Performance
Fire statements that apply, and those that do not
The table shows each fire-related point in the supplied sources and whether it covers the 200 mm item. Jawdah's single published fire statement, DIN 4102 B2, belongs to the PIR core material of its standard panels, not to this panel.
| Item | Covers the 200 mm panel? |
|---|---|
| Thickness 200 mm | Yes (Jawdah product list) |
| Core material | Not specified in the supplied data sheet |
| Reaction-to-fire class of the panel | Not specified in the supplied data sheet |
| Fire-resistance period of a wall | Not published; confirmed per project in writing |
| DIN 4102 B2 of the PIR core | No; stated for standard PIR panels only |
Applications
Handling and detailing a 200 mm wall
As general guidance, the deepest panel is also the heaviest per square metre and the most demanding to lift and position, so plan lifting equipment and panel lengths with the installer. Fasteners must be long enough to pass through the full depth into the frame, and every corner, base and opening trim must be sized for a 200 mm wall.
Order the matching trims from the wall flashings range at the same time as the panels, and keep panels stored flat, raised and protected from weather until they are fixed.
Choosing
What to request before ordering 200 mm panels
Ask Jawdah to confirm in writing the core material, the test standard and result, that the tested specimen was 200 mm deep, and the joint, fixing and height limits of the tested wall. Include the fire clause, the authority and the wall heights in your enquiry, and request the Tests and Technical Data Sheet for the consultant's review.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationSpecifications
200 mm panel values still to be issued
No data sheet for this item was supplied. The table lists what Jawdah needs to confirm in writing for the 200 mm thickness.
| Property | 200 mm panel |
|---|---|
| Panel thickness | 200 mm |
| Core material and density | Not specified in the supplied data sheet |
| Facing material and gauge | Not specified in the supplied data sheet |
| Panel weight and maximum length | Not specified in the supplied data sheet |
| Thermal values | Not specified in the supplied data sheet |
| Fire test standard, specimen and result | Not specified in the supplied data sheet |
To be confirmed by Jawdah for the 200 mm panel before specification.
Comparison
Choosing between 200 mm and the slimmer fire rated panels
Choose 200 mm when the wall schedule or the tested assembly calls for that depth, not because it is the largest number. If Jawdah's evidence covers a thinner panel for the same duty, the 150 mm or 100 mm panel gives a lighter, slimmer wall.
The 200 mm Cold Room Wall Panel shares the depth but is a PIR insulation product with its own data sheet. Its thermal data does not describe the fire rated item.
| Thickness | Listed by Jawdah | Fire data in supplied sources |
|---|---|---|
| 100 mm | Yes | Not specified in the supplied data sheet |
| 150 mm | Yes | Not specified in the supplied data sheet |
| 200 mm | Yes | Not specified in the supplied data sheet |

Key facts
- Jawdah lists a 200 mm Fire Rated Wall Sandwich Panel, the deepest of its 100, 150 and 200 mm fire-rated thicknesses.
- 200 mm is the largest wall panel thickness in the Jawdah range, shared with the cold room panel.
- The supplied data states no fire class, fire-resistance period, core material or thermal value for the 200 mm fire rated panel.
- The thickest panel is not proof of the longest fire performance; the core and the tested assembly decide.
- A 200 mm wall needs longer fasteners and trims sized for its depth (general guidance).
RFQ / BOQ checklist
- Panel: Fire Rated Wall Sandwich Panel, 200 mm
- Exact fire clause from the specification or fire strategy
- Material class, wall fire-resistance period, or both
- Required test standard and approving authority
- Wall locations, heights and areas
- Opening, junction and penetration details
- Facing, coating and colour
- Request for test reports and the technical data sheet
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
That cannot be assumed. No fire-resistance period is stated for any of the three thicknesses, and the core material and tested assembly matter more than depth alone.
Yes. 200 mm is the largest wall thickness in the Jawdah range; it is listed for the fire rated panel and for the cold room panel.
The core is not specified in the supplied data sheet. Ask Jawdah to confirm it in writing, together with the test report for the 200 mm panel.
No. The cold room panel is a separate PIR product with its own data sheet and thermal values; they do not describe the fire rated item.
Lifting and handling of the heavier panels, fasteners long enough for the full depth, and trims sized for a 200 mm wall, following the installer's method and the shop drawings.
The test reports for the 200 mm panel, the Technical Data Sheet and the Installation Manual. Jawdah lists the Tests and the Installation Manual as available in hard copy.

Next step
Confirm the 200 mm fire rated panel with Jawdah
Send the fire clause, authority, test standard and wall heights. Jawdah will confirm in writing what its evidence covers for 200 mm and quote.