T-Grid Systems · Cross Tee
T-Grid Cross Tee 1200 for Exposed Ceiling Modules
Cross Tee 1200 is the longer of the two Jawdah T-Grid cross tees: a 1200 mm member, listed in the data sheet as Cross-Tee (120), that locks between parallel main tees to turn them into a grid.
- Length
- 1200 mm
- Data sheet name
- Cross-Tee (120)
- Module formed
- 600x1200 mm
Overview
Quick answer
Cross Tee 1200 is a 1200 mm secondary member of the Jawdah T-Grid, recorded in the system contents as Cross-Tee (120). Its ends lock into main tees placed 1200 mm apart, producing 600x1200 mm modules, or 600x600 mm when Cross Tee 600 is added. It shares the T-grid material data: galvanised iron to ASTM A653M, pre-painted or aluminium cap, 0.28 mm regular or 0.32 mm heavy duty.
Overview
What Cross Tee 1200 adds to the grid
Where main tees give the ceiling its long lines, the 1200 mm cross tee gives it its first set of short lines, creating the 600x1200 mm module named in Jawdah's T-grid information.
This page explains the role of Cross Tee 1200, the data recorded for it, how it differs from Cross Tee 600, and what to include in an order.
A row of main tees on its own is only a set of rails. Cross Tee 1200 is the first member that ties those rails together. Each end carries a connector that engages a slot in the main tee web, so when a run of 1200 mm cross tees is clicked in at regular centres, the main tees are held at a fixed distance and the ceiling becomes a stable lattice.
In the Jawdah T-grid data sheet this member is listed as Cross-Tee (120) with a length of 1200 mm. The figure in brackets is a short form of the length, which is why the product list simply calls it Cross Tee 1200. It is offered within the T-24 and T-15 system types, so it is always ordered in the same type as the main tees it joins.
The connector geometry and profile height are not specified in the supplied data sheet; Jawdah confirms them on request.
How it works
How 1200 mm cross tees set the module
As general grid geometry, main tees are hung 1200 mm apart and Cross Tee 1200 members are clicked in between them at 600 mm centres. The result is a field of 600x1200 mm openings, one of the two module sizes the Jawdah T-grid information names. For a 600x600 mm ceiling, Cross Tee 600 members are then fitted across the middle of each opening, between neighbouring 1200 mm cross tees.
This is why Cross Tee 1200 appears in almost every T-grid ceiling, while the need for Cross Tee 600 depends on the tile size.
Applications
Ceilings that use Cross Tee 1200
Any Jawdah T-Grid ceiling with 600x1200 mm or 600x600 mm modules uses 1200 mm cross tees, in the spaces Jawdah lists for the grid: auditoriums, cinemas, halls, computer rooms, hospitals, shops, offices, utility rooms, airports, exhibition centres, conference rooms and studios. Rectangular 600x1200 mm tiles, often chosen for long corridors and open offices, need no Cross Tee 600 at all.
Compatibility
Members used with Cross Tee 1200
Order it with Main Tee 3600 (24) or Main Tee 3600 (15) of the same type, with Cross Tee 600 where 600x600 mm tiles are used, and with a perimeter trim at the walls. Tiles from the Jawdah Lay-In metal ceiling tile and gypsum ranges rest on the finished grid.
Choosing
Ordering Cross Tee 1200
Count cross tees from the reflected ceiling plan: one between each pair of main tees at every 600 mm, plus cut pieces at the walls. State the system type, thickness, cap and colour so the cross tees match the main tees in the same room.
- Same system type as the main tees.
- Same thickness and cap colour as the main tees.
- Allowance for perimeter cut pieces.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
Cross Tee 1200: recorded values
The values below come from the Jawdah T-grid technical data sheet and the parent T-Grid page.
| Property | Value |
|---|---|
| Designation in data sheet | Cross-Tee (120) |
| Length | 1200 mm |
| System type | T-24 or T-15, to match the main tees |
| Core material | Hot-dip galvanised iron, ASTM A653M |
| Cap | Pre-painted galvanised iron (ASTM A653M) or aluminium |
| Thickness | 0.28 mm regular / 0.32 mm heavy duty |
| Fire rating (raw material) | Class A1 |
| Connector and section dimensions | Not specified in the supplied data sheet |
Comparison
Cross Tee 1200 compared with Cross Tee 600
The two cross tees are not alternatives but partners. Cross Tee 1200 connects main tees; Cross Tee 600 subdivides the openings that the 1200 mm members create.
| Item | Data sheet name | Length | Connects |
|---|---|---|---|
| Cross Tee 1200 | Cross-Tee (120) | 1200 mm | Main tee to main tee |
| Cross Tee 600 | Cross-Tee (60) | 600 mm | Cross Tee 1200 to Cross Tee 1200 |

Key facts
- Cross Tee 1200 is the 1200 mm cross tee of the Jawdah T-Grid, listed as Cross-Tee (120).
- Cross Tee 1200 locks between main tees to form 600x1200 mm modules.
- Cross Tee 600 fitted between 1200 mm cross tees turns the module into 600x600 mm.
- Jawdah T-grid members are galvanised iron to ASTM A653M at 0.28 mm regular or 0.32 mm heavy duty.
- Cross tees are ordered in the same T-24 or T-15 type as the main tees.
RFQ / BOQ checklist
- Item: Cross Tee 1200 and quantity.
- System type: T-24 or T-15.
- Thickness: 0.28 mm regular or 0.32 mm heavy duty.
- Cap finish and colour.
- Module: 600x1200 mm or 600x600 mm.
- Matching main tees and perimeter trim.
- Delivery location and phasing.
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
The bracketed figure is a short form of the length. The Jawdah T-grid data sheet lists Cross-Tee (120) with a length of 1200 mm.
Fitted between main tees at 600 mm centres, it forms 600x1200 mm openings. Adding Cross Tee 600 across each opening gives 600x600 mm modules.
The Jawdah T-Grid is offered in T-24 and T-15 types, and cross tees are ordered in the same type as the main tees. Confirm availability for your type with Jawdah.
The Jawdah T-grid data lists 0.28 mm regular and 0.32 mm heavy duty. Match the cross tee thickness to the main tees.
Only for 600x600 mm modules. A 600x1200 mm ceiling is formed by main tees and 1200 mm cross tees alone.
Hot-dip galvanised iron complying with ASTM A653M, with a pre-painted galvanised iron or aluminium cap. The raw material is recorded as Class A1.

Next step
Request Cross Tee 1200
Send the ceiling plan, module, system type and cap finish, and the Jawdah team will quote Cross Tee 1200 with the matching main tees and trims.