T-Grid Main Tee 3600 (24) for T-24 Exposed Ceilings

Main Tee 3600 (24) is the 3600 mm primary runner of the Jawdah T-Grid in its T-24 type, the member that hangs from the soffit and carries the cross tees and tiles of an exposed ceiling.

Length
3600 mm
System type
T-24
Fire rating (raw material)
Class A1

Overview

Quick answer

Main Tee 3600 (24) is the long main runner of the Jawdah T-24 exposed ceiling grid. It is 3600 mm long, made of hot-dip galvanised iron to ASTM A653M with a pre-painted galvanised iron or aluminium cap, and listed at 0.28 mm regular or 0.32 mm heavy-duty thickness. Cross Tee 1200 and Cross Tee 600 lock into it to form the tile module.

Overview

What the Main Tee 3600 (24) does in a T-24 ceiling

The figure 3600 is the recorded length and (24) marks the T-24 system type named in the Jawdah T-grid technical data sheet.

This page sets out what the Jawdah data records for the main tee, what is still confirmed per project, and how to decide between this item and its T-15 sibling.

Every exposed grid is built on parallel main runners. In the Jawdah T-Grid that runner is the Main-Tee, listed in the system contents at 3600 mm. It is the only tee hung directly from the rod hangers, so it sets the level, the straightness and the spacing of the whole ceiling before a single cross tee is fitted.

The (24) in the product name ties this main tee to the T-24 type of the Jawdah T-grid technical data sheet. A T-24 ceiling should therefore be built with T-24 main tees and cross tees from the same order, because mixing types in one room breaks the visual line of the grid and the fit of the tiles. The T-15 variant, Main Tee 3600 (15), has its own page.

Physical dimensions of the profile beyond its length, such as web height or slot pitch, are not specified in the supplied data sheet and are confirmed by the Jawdah team when the order is placed.

Types

Main Tee 3600 (24) or Main Tee 3600 (15)

Jawdah lists two main tees of the same 3600 mm length. The choice between them follows the ceiling type, not the room size: the T-24 main tee belongs to a T-24 ceiling and the T-15 main tee to a T-15 ceiling. Choose this item when the tiles, drawings or existing ceiling call for T-24.

Thickness is the second decision. The 0.28 mm option is designated regular and the 0.32 mm option heavy duty; discuss the heavier option where the ceiling carries more light fittings or air terminals.

The two Jawdah 3600 mm main tees
ItemSystem typeLengthChoose it when
Main Tee 3600 (24)T-243600 mmThe ceiling is specified as a T-24 grid
Main Tee 3600 (15)T-153600 mmThe ceiling is specified as a T-15 grid

Applications

Where T-24 main tees are used

Jawdah lists its T-Grid for its metal and gypsum ceiling tiles in auditoriums, cinemas, halls, computer rooms, hospitals, shops, offices, utility rooms, airports, exhibition centres, conference rooms and studios. In each of these spaces the main tee forms the long lines of the ceiling, so it is usually the first grid item counted on a reflected ceiling plan.

Compatibility

Members and tiles that work with this main tee

On a T-24 ceiling the main tee receives Cross Tee 1200 and Cross Tee 600, while its ends rest on a perimeter trim such as the L-Angle Perimeter Trim. It hangs from rod hangers with adjustment clips and anchor bolts from the ceiling accessories range.

The Jawdah T-Grid is recorded as the suspension for Lay-In metal ceiling tiles and gypsum ceiling tiles. Confirm the tile edge (lay-on, lay-in or tegular) together with the grid type.

Installation

General installation guidance

As general practice, main tees are hung after the perimeter trim is fixed to a level line. Set the first run so that cut tiles at opposite walls end up similar in size, level each main tee at its hangers, and join lengths end to end where a room is longer than one tee. Cross tees are then clicked into the main tee to close the module. The Jawdah data states that the lock design makes the grid module demountable without tools.

  • Keep hangers plumb and tight before tiles are laid.
  • Do not mix T-24 and T-15 members in one ceiling.
  • Replace a bent main tee rather than straightening it.

Choosing

Ordering the Main Tee 3600 (24)

Quantities come from the ceiling plan: count main tee runs per room, allow for joints and cut ends, and state the thickness, cap and colour so every tee in a room matches. The Jawdah team confirms colours, imperial sizing and any value not shown above when it prepares the quotation.

Technical

Closer look

Detailed product imagery is being prepared.

In preparation

Jawdah data

Recorded data for Main Tee 3600 (24)

The rows below apply the Jawdah T-grid technical data sheet to this item. Only values the sheet states are shown; anything else is listed as not specified.

Main Tee 3600 (24): Jawdah data
PropertyRecorded value
Length3600 mm
System typeT-24
Core materialHot-dip galvanised iron complying with ASTM A653M
Cap (face)Pre-painted galvanised iron complying with ASTM A653M, or aluminium
Thickness0.28 mm regular / 0.32 mm heavy duty
Fire rating (raw material)Class A1
SizesMetric and imperial
Load value, profile height, slot pitchNot specified in the supplied data sheet

Class A1 describes the raw material only. It is not a fire-resistance period for an installed ceiling.

Key facts

  1. Main Tee 3600 (24) is the 3600 mm main runner of the Jawdah T-Grid for T-24 ceilings.
  2. The (24) in the name marks the T-24 system type of the Jawdah T-grid technical data sheet.
  3. Jawdah T-grid core profiles are hot-dip galvanised iron complying with ASTM A653M.
  4. Jawdah lists T-grid thickness as 0.28 mm regular or 0.32 mm heavy duty.
  5. The Jawdah T-grid raw material is recorded as fire rating Class A1.
  6. Cross Tee 1200 and Cross Tee 600 lock into the main tee to form the module.

RFQ / BOQ checklist

  • Item: Main Tee 3600 (24), quantity per room.
  • Thickness: 0.28 mm regular or 0.32 mm heavy duty.
  • Cap: pre-painted galvanised iron or aluminium, and colour.
  • Metric or imperial sizing.
  • Cross tees and perimeter trim needed with the main tees.
  • Tile type and edge detail.
  • Plenum depth and soffit type for hangers and anchors.
  • Delivery location and phasing.

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • It marks the T-24 system type named in the Jawdah T-grid technical data sheet. The item is the main tee for T-24 ceilings; the T-15 ceiling uses Main Tee 3600 (15).

  • The Jawdah T-grid system contents list the Main-Tee at 3600 mm, which is also the length in the product name.

  • The Jawdah T-grid data lists 0.28 mm as regular and 0.32 mm as heavy duty. State the thickness in the order so that all main tees in a ceiling match.

  • The core is hot-dip galvanised iron complying with ASTM A653M. The visible cap is pre-painted galvanised iron complying with ASTM A653M, or aluminium.

  • The Jawdah data records Class A1 for the raw material. This is a material classification, not a fire-resistance period for the installed ceiling.

  • No numerical load value is given in the supplied data sheet. Jawdah states that the system offers appropriate load-carrying capacities for tiles; heavier fittings are reviewed per project.

  • This is not recommended. Build each ceiling from members of one system type so that grid lines and tile seating stay consistent.