Roof Flashings · RF-104
RF-104 Internal Ridge Cap for Sandwich Panel Roofs
RF-104 Internal Ridge Cap is the coded Jawdah roof flashing that finishes the ridge of a sandwich panel roof from the inside, covering the joint between the two inner panel faces where the slopes meet.
- Code
- RF-104
- Position
- Ridge, room side
- Partner
- RF-103 External Ridge Cap
- Dimensions
- Confirmed per project

Overview
Quick answer
RF-104 Internal Ridge Cap is a formed metal trim fixed under the ridge of a sandwich panel roof, on the room side. It covers the gap between the inner faces of the two slopes, hides cut panel ends and the core, and closes the joint against dust and air movement. It is used with RF-103 External Ridge Cap where the panel underside is visible. Jawdah confirms its profile per project.
Overview
The ridge seen from inside
It is the room-side partner of the external ridge cap and matters wherever the underside of the roof panels is left exposed as the ceiling.
RF-104 is the fourth code in the Jawdah Roof Flashings range. Its girth, angle, gauge and material are not published. This page explains when an internal ridge cap is needed, what it closes and what Jawdah needs to confirm it.
A sandwich panel roof has two finished faces. In many warehouses, workshops, cold stores and sports halls there is no false ceiling, so the inner face of the roof panels is the ceiling. At the ridge, the inner faces of the two slopes meet with a gap and cut panel ends, and the insulation core is visible from below.
RF-104 Internal Ridge Cap closes that line from the inside. It is formed to the inside angle of the ridge and laps onto the inner face of both slopes, covering the panel ends and the joint. The weather is kept out by RF-103 External Ridge Cap above; RF-104 deals with what the room sees and what passes between the room and the ridge void.
This split matters for ordering: RF-103 is needed on every pitched panel roof, while RF-104 depends on whether the underside is exposed or sealed. Jawdah confirms the RF-104 section with the roof detail.
How it works
What the internal cap does
As general guidance, a room-side ridge trim serves four purposes:
- Covers the cut ends and core of both panels at the apex
- Closes the gap so dust and insects do not fall from the ridge void
- Limits air movement between the room and the ridge, which matters in cooled spaces
- Gives the exposed ceiling a straight, finished ridge line
Types
RF-104 next to the other ridge and edge codes
RF-104 is the only Jawdah roof flashing listed for the room side.
| Code | Side | Line |
|---|---|---|
| RF-104 Internal Ridge Cap | Room side | Ridge |
| RF-103 External Ridge Cap | Weather side | Ridge |
| RF-105 Gable Trim | Weather side | Sloping side edge |
| RF-106 Eave Trim | Weather side | Low roof edge |
Applications
Where RF-104 is used
RF-104 belongs in buildings where the roof underside stays visible or must be closed: warehouses and factories without a ceiling, cold rooms and controlled stores roofed with panels, food and clean areas where open joints overhead are not acceptable, and showrooms or halls with an exposed panel ceiling. Where a separate suspended ceiling hides the roof, the project may leave it out; that is a design decision to confirm with the consultant.
Selection pitfalls
Internal ridge mistakes
The internal ridge is often forgotten until the roof is closed.
- Leaving RF-104 out of the order where the underside is visible
- Matching the trim to the outside colour instead of the inner face
- Fitting it after services have been run along the ridge
- Open gaps at the ends where the ridge meets the gable
Choosing
Do you need RF-104?
If the roof panel underside is the finished ceiling, or the room is cooled or must stay clean, include RF-104 for every ridge, with the same length as RF-103. Note the inner facing and colour. Send both ridge codes together with the Roof Flashings list and the roof panel RFQ; for cold rooms, add the Cold Room Wall Panel layout.
Technical
Closer look


Materials
Matching the inner face
Jawdah roof panels are faced with PPGI, aluminium, stainless steel or galvanised iron, with polyester or PVDF coating; the standard colour is Cloud White (RAL 9002). The inner face of a roof panel is not always the same facing or colour as the outer face, so state the facing RF-104 must match. In hygienic or wash-down areas, ask Jawdah to confirm a trim material suited to that environment.
Specifications
RF-104 data status
No technical data sheet covers Jawdah flashings. The values below are confirmed in the quotation.
| Property | Value |
|---|---|
| Code and name | RF-104 Internal Ridge Cap |
| Range | Roof Flashings |
| Girth and lap onto each slope | Not specified in the supplied data sheet |
| Angle | Set by the roof pitch; confirmed per project |
| Material, thickness and colour | Confirmed per project |

Key facts
- RF-104 Internal Ridge Cap is a coded item in the Jawdah Roof Flashings range.
- RF-104 finishes the ridge of a sandwich panel roof on the room side.
- RF-104 is used with RF-103 External Ridge Cap where the panel underside is exposed.
- RF-104 should match the inner panel facing, which can differ from the outer face.
- Jawdah confirms RF-104 profile, material and colour per project.
RFQ / BOQ checklist
- Roof plan with ridges and whether each underside is exposed
- Ridge lengths for RF-104 (normally equal to RF-103)
- Roof pitch
- Inner panel facing and colour
- Room use: warehouse, cold room, food or clean area
- Delivery with the roof panel package or separately
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
A coded Jawdah roof flashing that finishes the ridge of a sandwich panel roof on the room side, covering the joint between the inner panel faces.
No. It is needed where the panel underside is visible or the room must be closed, such as warehouses without ceilings and cold rooms.
No. RF-103 keeps the weather out on top; RF-104 finishes the inside. Where both are needed they are ordered together.
The colour and facing of the inner panel face, which may differ from the outside. State it separately in the RFQ.
An open ridge joint lets air move between the cooled room and the ridge void and leaves the core exposed overhead.
No. Girth, lap, angle, material and thickness are confirmed by Jawdah per project.

Next step
Finish the ridge inside and out
Send the roof plan, pitch and inner facing. The Jawdah team will confirm RF-104 and RF-103 together with the roof panels.