Jawdah Industrial Co. Ltd.

Roof Flashings · RF-103

RF-103 External Ridge Cap for Sandwich Panel Roofs

RF-103 External Ridge Cap is the coded Jawdah roof flashing that covers the apex of a sandwich panel roof from the outside, lapping over the top ends of both slopes and closing the gap where they meet.

Code
RF-103
Position
Roof apex, outside
Works with
RF-107 closures, RF-104 inside
Dimensions
Confirmed per project
RF-103 External Ridge Cap, 3D render of the folded steel flashing profile for sandwich panel roofs

Overview

Quick answer

RF-103 External Ridge Cap is a formed metal capping fixed over the ridge of a sandwich panel roof. It laps over both slopes, sits on profile fillers that close the rib voids, and is fixed at close spacing because wind suction is high at the ridge. It is the outside ridge member; RF-104 finishes the inner side. Jawdah confirms the RF-103 profile per project.

Overview

What the external ridge cap closes

The ridge is the highest line of the roof and one of the most wind-exposed, so the cap has to stay sealed against driven rain and suction.

RF-103 is the third code in the Jawdah Roof Flashings range. Its girth, angle, gauge and material are not published; this page explains how an external ridge cap works with fillers and fixings, how it differs from RF-104, and what Jawdah needs to confirm it.

Where two roof slopes rise to meet, the panels stop short of each other at the apex. Their top ends leave a gap along the ridge and, under each panel end, the open voids of the high ribs. Rain, dust and wind would pass straight through without a cover.

RF-103 External Ridge Cap is that cover. It is shaped to the ridge angle, laps down over the top of each slope, and sits on fillers that block the rib voids underneath. Water landing on it is shed onto the panels on both sides and runs down the troughs to the eaves.

Jawdah codes the ridge in two parts. RF-103 is the weather side, on top of the roof. RF-104 Internal Ridge Cap finishes the same junction from below, on the room side of the panels. The exact RF-103 section is confirmed by Jawdah against the roof pitch and panel profile.

How it works

Fillers, laps and fixings at the ridge

As general guidance, a ridge detail has three layers: profile fillers shaped to the rib, sealant on top of the fillers, and the cap fixed through into the ribs or the purlin below. On low pitches the top ends of the panel troughs are often turned up so wind cannot drive water back under the cap. The coded closure in the Jawdah range is RF-107 Foam Closure Trim.

Types

External or internal ridge cap?

The two ridge codes are not alternatives; most exposed-ceiling roofs use both.

RF-103 and RF-104 compared (general guidance)
AspectRF-103 External Ridge CapRF-104 Internal Ridge Cap
Side of the roofOutside, on top of the panelsInside, under the panels
Main jobKeeps weather out of the ridgeFinishes and closes the inner face
Exposed toRain, sun, wind suctionRoom conditions
Needed whenEvery pitched panel roofThe panel underside is visible or sealed

Applications

Roof panels RF-103 serves

RF-103 caps the ridge of Jawdah high-rib roofs, both the 3-Rib Roof Panel and the 5-Rib Roof Panel. The cap itself is usually flat where it laps the panels, but its fillers must follow the rib shape, so state the variant. Roof panels are faced with PPGI, aluminium, stainless steel or galvanised iron with polyester or PVDF coating; ask for the cap to match the roof face.

Installation

Fitting the ridge cap

Close the ridge only after both slopes are fixed and aligned. Seat the fillers on the panel ribs, apply sealant, then lay the cap lengths starting from the end away from the prevailing wind so laps face downwind. Fix at the closer spacing the engineer sets for ridges and edges, and seal every lap.

Selection pitfalls

Ridge cap failures

Ridge problems show up after the first windy rain.

  • Missing or wrong-profile fillers under the cap
  • Laps facing into the prevailing wind
  • Cap fixed at the same spacing as the roof field
  • Panels stopping too far from the apex for the cap to lap
  • Cap angle not matched to the roof pitch

Choosing

Specifying RF-103

Mark each ridge on the roof plan as RF-103 with its length and the roof pitch. Note the panel variant and colour, and say whether the underside is visible so the matching RF-104 can be included. Send it with the Roof Flashings list and the roof panel RFQ.

Technical

Closer look

Approved photography of the product and its finish.
RF-103 External Ridge Cap, 3D render of the folded steel flashing profile for sandwich panel roofs
External ridge cap flashing profile (RF-103) for sandwich panel roofs

Specifications

RF-103 data status

No technical data sheet covers Jawdah flashings. The RF-103 values below are confirmed in the quotation.

RF-103 External Ridge Cap data status
PropertyValue
Code and nameRF-103 External Ridge Cap
RangeRoof Flashings
Girth and lap onto each slopeNot specified in the supplied data sheet
AngleSet by the roof pitch; confirmed per project
Material and thicknessNot specified in the supplied data sheet

Key facts

  1. RF-103 External Ridge Cap is a coded item in the Jawdah Roof Flashings range.
  2. RF-103 covers the apex of a sandwich panel roof from the outside and laps over both slopes.
  3. A ridge cap sits on profile fillers that close the rib voids, such as RF-107 Foam Closure Trim.
  4. RF-104 Internal Ridge Cap finishes the same ridge on the room side.
  5. Jawdah confirms RF-103 girth, angle and material per project.

RFQ / BOQ checklist

  • Roof plan with every ridge marked RF-103 and its length
  • Roof pitch of each slope
  • Roof panel variant: 3-rib or 5-rib
  • Prevailing wind direction and exposure
  • Whether the underside is visible (RF-104 needed)
  • Colour and material to match the roof
  • Fillers and sealants to supply with the cap

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • A coded Jawdah roof flashing that covers the apex of a sandwich panel roof from the outside, lapping over both slopes.

  • RF-103 is the weather-side cap on top of the roof. RF-104 Internal Ridge Cap finishes the same ridge on the room side under the panels.

  • The high ribs leave open voids at the panel ends. Fillers close them so wind, rain, dust and birds cannot pass under the cap.

  • Wind suction is higher at ridges, edges and corners, so caps and panels there are normally fixed at closer spacing set by the engineer.

  • Yes. The cap is formed to the ridge angle, so state the pitch of both slopes in the RFQ.

  • No. Girth, lap, angle, material and thickness are confirmed by Jawdah per project.

Next step

Get your ridge detail quoted