Jawdah Industrial Co. Ltd.

5-Rib Roof Panels · 100 mm

5-Ribs Roof Sandwich Panels — 100 mm

The 100 mm 5-rib roof panel is the most insulating five-rib panel with published values in Jawdah's PIR roof range, combining a 100 mm core with a closely ribbed outer sheet.

Profile
High rib, 5 ribs
Core thickness
100 mm
R-value (core)
4.35 m²·K/W
U-value (core)
0.23 W/m²·K
5-Ribs Roof Sandwich Panels 100 mm

Overview

Quick answer

Jawdah's 100 mm 5-rib roof panel has a 100 mm PIR core under a five-rib high-rib outer sheet. Jawdah's data sheet gives R 4.35 m²·K/W and U 0.23 W/m²·K, the highest R-value Jawdah publishes for a roof panel. It suits temperature-controlled facilities and continuously cooled buildings, including those with visible roofs. Spans, weight and five-rib geometry are confirmed per project.

Overview

The deepest five-rib panel with published values

Its data sheets give R 4.35 m²·K/W and U 0.23 W/m²·K for the core.

It is aimed at temperature-controlled facilities where the roof must keep heat out all day and still present a fine, even surface. Compare it with the 75 mm and 150 mm five-rib panels below; the profile is on the 5-Rib Roof Sandwich Panels page.

This panel bonds a 100 mm rigid PIR core between a five-rib high-rib external sheet and a semi-corrugated or plain internal sheet. The close rib pattern gives the outside a uniform texture, while the deep core does the thermal work.

Its core R-value of 4.35 m²·K/W is the top of the published five-rib table, against 1.30 at 30 mm. Jawdah lists temperature-controlled facilities among its roof uses, and as general practice this is the thickness such buildings start from when the roof faces full sun. Because the panel is deeper and heavier than the thinner versions, fasteners, fillers and edge trims must be sized for it, and handling of long lengths needs planning on site.

Types

Five ribs or three at 100 mm

The 3-rib 100 mm panel has the same R 4.35 and U 0.23. Five ribs give a more uniform face and shorter bays for roofs that are seen; three ribs give wider troughs for long, plain storage roofs. Span data is specific to each profile.

3-rib and 5-rib at 100 mm
Aspect3-rib, 100 mm5-rib, 100 mm
Core R-value (m²·K/W)4.354.35
Core U-value (W/m²·K)0.230.23
Rib patternBold, widely spacedFiner, closely spaced
TroughsWideNarrower
Geometry and spansConfirmed per projectConfirmed per project

Pattern and trough rows are general guidance on rib count, not Jawdah measurements.

Applications

Temperature-controlled roofs for 100 mm five-rib panels

As general guidance, the 100 mm five-rib panel is considered for roofs over spaces kept cool around the clock, especially where the roof or soffit is seen:

  • Temperature-controlled storage and distribution buildings
  • Food and pharmaceutical facilities with visible roofs
  • Continuously air-conditioned commercial buildings
  • Covered areas of temperature-controlled loading docks

Choosing

Ordering 100 mm 5-rib panels

Run the project's thermal calculation with the core value of R 4.35 m²·K/W plus surface resistances and bridging. Then send Jawdah the roof drawings, slope, purlin spacing, wind exposure, design temperature and panel lengths, and ask for the five-rib span at 100 mm, weight, fastener length and matching trims.

The roof category page labels this thickness 100/130 mm, while the data sheets calculate from the 100 mm core; confirm the depth at the ribs before detailing ridges and eaves.

Technical

Closer look

Detailed product imagery is being prepared.

In preparation

Jawdah data

Five-rib data sheet entries at 100 mm

Jawdah's five-rib data sheet lists a 100 mm row. The family facts below come from Jawdah's parent roof pages.

  • Core thickness: 100 mm, 5-rib high-rib profile
  • Thermal row: R 4.35 m²·K/W, U 0.23 W/m²·K (core only)
  • Insulation core: PIR; DIN 4102 B2 stated for the core material
  • Internal face: semi-corrugated or plain
  • Facings: PPGI, aluminium, stainless steel or galvanised iron
  • Coating: polyester or PVDF; Cloud White standard
  • Roof category designation: 100/130 mm

Specifications

100 mm 5-rib values and remaining data gaps

As in the data sheets, R is the 100 mm core divided by λ = 0.023 W/m·K and U is the inverse; both refer to the core only, without surface resistances or bridging through fixings. Five-rib cover width, rib height, span and weight at 100 mm are not given in the supplied data.

5-rib roof panel, 100 mm: Jawdah data-sheet values
PropertyValue
Core thickness100 mm
Insulation corePIR, λ = 0.023 W/m·K (calculation basis)
R-value (core only)4.35 m²·K/W
U-value (core only)0.23 W/m²·K
ProfileHigh rib, 5 ribs per panel width
Internal faceSemi-corrugated or plain
Cover width, rib height and spacingNot specified in the supplied data sheet
Span, load and panel weightNot specified in the supplied data sheet

Comparison

100 mm against the other five-rib thicknesses

From the 75 mm panel to 100 mm the five-rib core R-value rises from 3.26 to 4.35 m²·K/W. The deeper 5-rib panel is listed, and Jawdah confirms its thermal values with the quotation. For a confirmed figure today, 100 mm is the top of the five-rib table.

5-rib roof panel thicknesses (Jawdah data sheet)
Core thicknessR-value (m²·K/W)U-value (W/m²·K)
30 mm1.300.77
50 mm2.170.46
75 mm3.260.31
100 mm4.350.23

Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts

  1. Jawdah lists a 100 mm core thickness of its 5-rib high-rib PIR roof sandwich panel.
  2. The 100 mm 5-rib panel has a core R-value of 4.35 m²·K/W and a U-value of 0.23 W/m²·K, the highest published five-rib values.
  3. Jawdah's five-rib data sheet publishes thermal values for 30, 50, 75 and 100 mm.
  4. 100 mm five-rib panels suit temperature-controlled facilities, including those with visible roofs (general guidance).
  5. Weight, spans and five-rib geometry at 100 mm are confirmed by Jawdah per project.

RFQ / BOQ checklist

  • Profile and thickness: 5-rib, 100 mm
  • Roof area, slope and purlin spacing
  • Wind exposure and maintenance traffic
  • External facing, coating and colour
  • Internal face: semi-corrugated or plain
  • Panel lengths and quantities
  • Matching ridge, eave and gable flashings and fillers
  • Project location and delivery date

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • R 4.35 m²·K/W for the 100 mm core, with a U-value of 0.23 W/m²·K, from the five-rib data sheets. Surface resistances and bridging are not included.

  • It is the thickest with a published value. A 150 mm five-rib thickness is also listed, but its thermal value is confirmed by Jawdah on request.

  • Temperature-controlled facilities are among Jawdah's roof applications, and 100 mm is the usual starting thickness for them. Confirm against the facility's design temperature.

  • Yes. Both have R 4.35 m²·K/W and U 0.23 W/m²·K at 100 mm. Choose the profile by appearance, drainage and span data.

  • As general guidance, the deeper panel is heavier, needs longer fasteners and trims and fillers sized for its depth, and long lengths need careful lifting.

  • It is the paired designation used on the roof category page. The data sheets calculate from the 100 mm core; Jawdah confirms the depth at the ribs.

Next step

Request 100 mm 5-rib roof panels

Send the roof drawings, design temperature, purlin spacing and colour. Jawdah will confirm five-rib spans, fixings, trims and a quotation for 100 mm.