5-Rib Roof Panels · 75 mm
5-Ribs Roof Sandwich Panels — 75 mm
The 75 mm 5-rib roof panel brings a 75 mm PIR core to Jawdah's finely ribbed five-rib profile, for roofs that must look tidy and keep a cooled building comfortable.
- Profile
- High rib, 5 ribs
- Core thickness
- 75 mm
- R-value (core)
- 3.26 m²·K/W
- U-value (core)
- 0.31 W/m²·K

Overview
Quick answer
The Jawdah 75 mm 5-rib roof panel is a high-rib PIR sandwich panel with five ribs per width and a 75 mm core rated in its data sheets at R 3.26 m²·K/W and U 0.31 W/m²·K. It suits cooled commercial buildings and temperature-controlled facilities whose roofs are seen, where both a fine surface and solid insulation matter. Five-rib spans and geometry are confirmed by Jawdah per project.
Overview
A five-rib roof with a deeper core
Jawdah's data sheet gives the core R 3.26 m²·K/W and U 0.31 W/m²·K.
This page shows where that combination of appearance and insulation pays off, compares 75 mm with the 50 mm and 100 mm five-rib panels, and lists what Jawdah needs. Profile background is on the 5-Rib Roof Sandwich Panels page.
The 75 mm panel keeps the five-rib face, with short flat bays and a regular texture, and backs it with a 75 mm rigid PIR core and a semi-corrugated or plain inner sheet. The result is a roof that reads cleanly from outside and provides a finished ceiling inside.
With an R-value of 3.26 m²·K/W, the core insulates half as much again as the 50 mm panel. That is the level commonly considered when a building is air-conditioned for most of the day and the roof is also on show: shopping and service buildings on main roads, offices attached to production halls, or temperature-controlled facilities with visible eaves and canopies. For continuous cold storage, the 100 mm panel or deeper is the usual comparison.
Types
Five ribs or three at 75 mm
At 75 mm the 3-rib panel offers the same R 3.26 and U 0.31. Pick five ribs when the roof surface or soffit is seen and a regular texture is wanted; pick three ribs for long hangar or warehouse roofs with wide troughs. Ask Jawdah for span data for the profile you choose.
| Aspect | 3-rib, 75 mm | 5-rib, 75 mm |
|---|---|---|
| Core R-value (m²·K/W) | 3.26 | 3.26 |
| Core U-value (W/m²·K) | 0.31 | 0.31 |
| Rib pattern | Bold, widely spaced | Finer, closely spaced |
| Troughs | Wide | Narrower |
| Geometry and spans | Confirmed per project | Confirmed per project |
Pattern and trough rows are general guidance on rib count, not Jawdah measurements.
Applications
Cooled buildings with visible five-rib roofs
Temperature-controlled facilities and commercial facilities both appear in Jawdah's roof applications. As general guidance, a 75 mm five-rib roof is a fit where cooling runs through the working day and the roof or its edge is part of the façade.
- Air-conditioned retail and service buildings
- Offices and amenity blocks beside production halls
- Temperature-controlled facilities with visible eaves
- Enclosed areas under fuel station canopies
Choosing
Getting 75 mm 5-rib panels quoted
Confirm the roof's thermal target, then agree the external colour and internal face with the design team. Send Jawdah the roof drawings, slope, purlin spacing, wind exposure and panel lengths, and ask for the five-rib span at 75 mm, panel weight, and matched fillers and trims.
The roof category page names this thickness 75/105 mm; the data sheets calculate from the 75 mm core. Confirm the depth at the ribs for the fascia and flashing details.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
75 mm in the five-rib data sheets
Jawdah's five-rib data sheet lists a 75 mm row. The family-level entries below come from the parent roof pages.
- Core thickness: 75 mm, 5-rib high-rib profile
- Thermal row: R 3.26 m²·K/W, U 0.31 W/m²·K (core only)
- Insulation core: PIR; DIN 4102 B2 stated for the core material
- Internal face: semi-corrugated or plain
- Facings: PPGI, aluminium, stainless steel or galvanised iron
- Coating: polyester or PVDF; Cloud White standard
- Roof category designation: 75/105 mm
Specifications
What is fixed and what is pending at 75 mm
The R-value is the 75 mm core over λ = 0.023 W/m·K, and U is its reciprocal, as the data sheets set out. Surface resistances and the bridging effect of fixings are not included. The supplied data does not cover five-rib dimensions, spans or the panel weight at this depth.
| Property | Value |
|---|---|
| Core thickness | 75 mm |
| Insulation core | PIR, λ = 0.023 W/m·K (calculation basis) |
| R-value (core only) | 3.26 m²·K/W |
| U-value (core only) | 0.31 W/m²·K |
| Profile | High rib, 5 ribs per panel width |
| Internal face | Semi-corrugated or plain |
| Cover width, rib height and spacing | Not specified in the supplied data sheet |
| Span, load and panel weight | Not specified in the supplied data sheet |
Comparison
75 mm among the five-rib thicknesses
Within the five-rib range the core R-value climbs from 2.17 at the 50 mm panel to 3.26 at 75 mm and 4.35 at the 100 mm panel. Choose the step that meets the thermal target with the least depth.
| Core thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 30 mm | 1.30 | 0.77 |
| 50 mm | 2.17 | 0.46 |
| 75 mm | 3.26 | 0.31 |
| 100 mm | 4.35 | 0.23 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts
- Jawdah lists a 75 mm core thickness of its 5-rib high-rib PIR roof sandwich panel.
- The 75 mm 5-rib panel has a core R-value of 3.26 m²·K/W and a U-value of 0.31 W/m²·K (Jawdah data sheet).
- 75 mm sits between the 50 mm (R 2.17) and 100 mm (R 4.35) five-rib panels.
- 75 mm five-rib panels suit cooled commercial buildings and temperature-controlled facilities with visible roofs (general guidance).
- Five-rib spans and geometry at 75 mm are confirmed by Jawdah per project.
RFQ / BOQ checklist
- Profile and thickness: 5-rib, 75 mm
- Roof area, slope and purlin spacing
- Wind exposure and maintenance traffic
- External facing, coating and colour
- Internal face: semi-corrugated or plain
- Panel lengths and quantities
- Matching ridge, eave and gable flashings and fillers
- Project location and delivery date
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
R 3.26 m²·K/W for the 75 mm core, with a U-value of 0.31 W/m²·K, according to the five-rib data sheets. The values exclude surface resistances.
Projects with cooled buildings whose roofs are visible, such as retail and service buildings, offices beside production halls and temperature-controlled facilities with exposed eaves.
If the thermal target needs a core R-value above 3.26 m²·K/W, choose 100 mm, which reaches 4.35. Otherwise 75 mm meets the need with a shallower, lighter panel.
Yes. Jawdah's 3-rib and 5-rib data sheets both list R 3.26 m²·K/W and U 0.31 W/m²·K at 75 mm. The rib profile changes appearance, trough width and span data.
It is the roof category page's paired designation for this thickness. The data sheets calculate from the 75 mm core; Jawdah confirms the depth at the ribs.
Yes. Jawdah roof panels have a semi-corrugated or plain internal face; choose the one that suits the finished ceiling.

Next step
Get 75 mm 5-rib panels quoted
Share the roof drawings, thermal target, colour and internal face. Jawdah will confirm five-rib spans, trims and a quotation for 75 mm.