5-Rib Roof Panels · 50 mm
5-Ribs Roof Sandwich Panels — 50 mm
The 50 mm 5-rib roof panel pairs Jawdah's closely ribbed five-rib profile with a 50 mm PIR core, the second step in the five-rib thickness range.
- Profile
- High rib, 5 ribs
- Core thickness
- 50 mm
- R-value (core)
- 2.17 m²·K/W
- U-value (core)
- 0.46 W/m²·K

Overview
Quick answer
Jawdah's 50 mm 5-rib roof panel is a high-rib PIR sandwich panel with five closely spaced ribs per width and a 50 mm core. Jawdah's data sheet gives R 2.17 m²·K/W and U 0.46 W/m²·K for the core. It fits commercial buildings and visible roofs that need moderate insulation and a neat rib pattern. Five-rib geometry and spans are confirmed by Jawdah per project.
Overview
Where the 50 mm five-rib panel fits
Its data sheets record R 2.17 m²·K/W and U 0.46 W/m²·K for the core, with five ribs across each panel.
It suits commercial and mixed-use roofs where the roof line is visible and some insulation is needed. Compare it here with the 30 mm and 75 mm five-rib panels; the profile is covered on the 5-Rib Roof Sandwich Panels page.
Here a 50 mm PIR core sits between the five-rib high-rib outer sheet and a semi-corrugated or plain inner face. The close rib spacing breaks the surface into short bays, so the roof reads as a fine, regular texture from the street or from neighbouring buildings, and local marks are less noticeable.
The 50 mm core moves the five-rib roof from shade structure to building envelope: its R-value of 2.17 m²·K/W is well above the 1.30 of the 30 mm panel. That makes it a sensible general-practice choice for roofs over shops, showrooms, offices or service buildings that are cooled during working hours, where the roof edge and fascia are part of the building's appearance and a full temperature-controlled build-up is not required.
Types
Five ribs or three at 50 mm
The 3-rib 50 mm panel has identical core values. The difference is visual and structural: five ribs give a finer, more uniform face and shorter bays, three ribs give wider troughs suited to long warehouse runs. Each has its own span data.
| Aspect | 3-rib, 50 mm | 5-rib, 50 mm |
|---|---|---|
| Core R-value (m²·K/W) | 2.17 | 2.17 |
| Core U-value (W/m²·K) | 0.46 | 0.46 |
| Rib pattern | Bold, widely spaced | Finer, closely spaced |
| Troughs | Wide | Narrower |
| Geometry and spans | Confirmed per project | Confirmed per project |
Pattern and trough rows are general guidance on rib count, not Jawdah measurements.
Applications
Visible roofs where 50 mm five-rib panels work
Jawdah lists commercial facilities among its roof applications, and a finer rib pattern is often chosen where the roof is visible. As general guidance, 50 mm five-rib panels suit:
- Retail units and showrooms with visible roof edges
- Office and service buildings on industrial sites
- Low roofs overlooked by neighbouring buildings
- Canopy areas that enclose a small cooled space
Choosing
Requesting 50 mm 5-rib panels
Choose the colour, coating and internal face with the architect, since the roof is part of the elevation. Then send Jawdah the roof drawings, slope, purlin spacing, wind exposure and lengths, and ask for five-rib span data at 50 mm, matching fillers and the eave and gable trims.
On the roof category page the thickness appears as 50/80 mm; the data sheets work from the 50 mm core, so confirm the depth at the ribs before detailing.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
Data-sheet entries that apply to 50 mm
Jawdah's five-rib data sheet lists a 50 mm row. The other facts listed apply across Jawdah's high-rib PIR roof family.
- Core thickness: 50 mm, 5-rib high-rib profile
- Thermal row: R 2.17 m²·K/W, U 0.46 W/m²·K (core only)
- Insulation core: PIR; DIN 4102 B2 stated for the core material
- Internal face: semi-corrugated or plain
- Facings: PPGI, aluminium, stainless steel or galvanised iron
- Coating: polyester or PVDF; Cloud White standard
- Roof category designation: 50/80 mm
Specifications
Recorded values and open data for the 50 mm 5-rib panel
Following the data sheets' method, the R-value equals the 50 mm core thickness over λ = 0.023 W/m·K, and U is the inverse. The figures describe the core only. Five-rib geometry, purlin spans and panel weight at 50 mm are among the items Jawdah confirms per project.
| Property | Value |
|---|---|
| Core thickness | 50 mm |
| Insulation core | PIR, λ = 0.023 W/m·K (calculation basis) |
| R-value (core only) | 2.17 m²·K/W |
| U-value (core only) | 0.46 W/m²·K |
| Profile | High rib, 5 ribs per panel width |
| Internal face | Semi-corrugated or plain |
| Cover width, rib height and spacing | Not specified in the supplied data sheet |
| Span, load and panel weight | Not specified in the supplied data sheet |
Comparison
50 mm compared with the other five-rib thicknesses
In the five-rib range, 50 mm lifts the core R-value from 1.30 at the 30 mm panel to 2.17, and the 75 mm panel takes it to 3.26. For buildings cooled around the clock, look further up the table.
| Core thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 30 mm | 1.30 | 0.77 |
| 50 mm | 2.17 | 0.46 |
| 75 mm | 3.26 | 0.31 |
| 100 mm | 4.35 | 0.23 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts
- Jawdah lists a 50 mm core thickness of its 5-rib high-rib PIR roof sandwich panel.
- The 50 mm 5-rib panel has a core R-value of 2.17 m²·K/W and a U-value of 0.46 W/m²·K (Jawdah data sheet).
- From 30 mm to 50 mm the five-rib core R-value rises from 1.30 to 2.17 m²·K/W.
- 50 mm five-rib panels suit commercial roofs and visible roof edges that need moderate insulation (general guidance).
- Five-rib cover width, rib geometry and spans at 50 mm are confirmed by Jawdah per project.
RFQ / BOQ checklist
- Profile and thickness: 5-rib, 50 mm
- Roof area, slope and purlin spacing
- Wind exposure and maintenance traffic
- External facing, coating and colour
- Internal face: semi-corrugated or plain
- Panel lengths and quantities
- Matching ridge, eave and gable flashings and fillers
- Project location and delivery date
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
R 2.17 m²·K/W and U 0.46 W/m²·K for the 50 mm core, from the five-rib data sheets and calculated with λ = 0.023 W/m·K. Surface resistances are not included.
Commercial facilities are among Jawdah's roof applications, and the fine five-rib pattern suits roofs that are on view. Check the thermal target and confirm spans with Jawdah.
The core R-value rises from 1.30 to 2.17 m²·K/W, so the 50 mm panel suits enclosed, cooled spaces better, while 30 mm fits open canopies.
No. Both have R 2.17 m²·K/W and U 0.46 W/m²·K at 50 mm. They differ in rib pattern, trough width and span data.
It is the paired designation used there for this thickness. The data sheets calculate from the 50 mm core; Jawdah confirms the overall depth at the ribs.
Jawdah roof panels are listed with PPGI, aluminium, stainless steel or galvanised iron facings, polyester or PVDF coating, and Cloud White as the standard colour.

Next step
Ask for 50 mm 5-rib roof panels
Send the roof drawings, colour, internal face and purlin spacing. Jawdah will confirm five-rib spans, trims and a quotation for the 50 mm panel.