3-Rib Roof Panels · 50 mm
3-Ribs Roof Sandwich Panels — 50 mm
The 50 mm 3-rib roof panel is the second thickness in Jawdah's three-rib PIR roof range and the first that moves a roof clearly away from the thin 30 mm build-up.
- Profile
- High rib, 3 ribs
- Core thickness
- 50 mm
- R-value (core)
- 2.17 m²·K/W
- U-value (core)
- 0.46 W/m²·K

Overview
Quick answer
Jawdah's 50 mm 3-rib roof panel has a 50 mm PIR core under a three-rib high-rib outer sheet. Its data sheets give a core R-value of 2.17 m²·K/W and a U-value of 0.46 W/m²·K, calculated from λ = 0.023 W/m·K. It is a common middle choice for warehouses and factories that need more insulation than 30 mm offers. Spans and rib geometry are confirmed per project.
Overview
The 50 mm 3-rib panel at a glance
Jawdah's data sheet gives it R 2.17 m²·K/W and U 0.46 W/m²·K for the core.
Use this page to decide whether 50 mm suits a warehouse or factory roof, to compare it with the 30 mm and 75 mm panels, and to collect what Jawdah needs for a quotation. General profile information is on the 3-Rib Roof Sandwich Panels page.
This is a single-piece insulated roof panel. A 50 mm polyisocyanurate core is bonded to a three-rib high-rib external sheet, whose deep ribs carry the load between purlins and lift the side laps above the water, and to an internal sheet that stays semi-corrugated or plain as the ceiling below.
Moving from 30 mm to 50 mm brings the core U-value down from 0.77 to 0.46 W/m²·K, a large change for a modest increase in depth. For many large roofs that are neither open sheds nor cold stores, this is where a three-rib roof starts to keep the space below noticeably more comfortable while the panel stays light enough for long lengths and fast fixing.
Types
Three ribs or five ribs at 50 mm
The 5-rib 50 mm panel has the same core values, R 2.17 and U 0.46, because thermal performance depends on the core. Choose between them by the roof: three ribs favour long industrial runs and wide drainage troughs, five ribs a finer, more uniform surface where the roof or its soffit is seen.
| Aspect | 3-rib, 50 mm | 5-rib, 50 mm |
|---|---|---|
| Core R-value (m²·K/W) | 2.17 | 2.17 |
| Core U-value (W/m²·K) | 0.46 | 0.46 |
| Rib pattern | Bold, widely spaced | Finer, closely spaced |
| Troughs | Wide | Narrower |
| Geometry and spans | Confirmed per project | Confirmed per project |
Pattern and trough rows are general guidance on rib count, not Jawdah measurements.
Applications
Buildings that often use a 50 mm 3-rib roof
Jawdah's roof applications include warehouses, factories, industrial roofs and commercial facilities. A 50 mm core is a frequent general-practice choice for these when the building is ventilated or lightly cooled and the roof is the main source of heat gain.
- General warehouses and distribution sheds
- Factory and production hall roofs
- Workshops with spot cooling or ventilation
- Commercial buildings with large roof areas
Choosing
Ordering 50 mm 3-rib panels
Confirm that U 0.46 W/m²·K meets the roof target, then give Jawdah the roof plan, slope, purlin spacing, wind exposure and required lengths. Jawdah will confirm the three-rib span at 50 mm, the panel weight, and the matching fillers and flashings for your order.
On the roof category page this thickness appears as 50/80 mm; the data sheets base their values on the 50 mm core, so confirm the depth at the ribs with Jawdah for detailing.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
Data-sheet facts for the 50 mm 3-rib panel
Jawdah's 3-rib data sheet carries a 50 mm row with the values shown below. The other points apply to the whole high-rib PIR roof family on the parent pages.
- Core thickness: 50 mm, 3-rib high-rib profile
- Thermal row: R 2.17 m²·K/W, U 0.46 W/m²·K (core only)
- Insulation core: PIR; DIN 4102 B2 stated for the core material
- Internal face: semi-corrugated or plain
- Facings: PPGI, aluminium, stainless steel or galvanised iron
- Coating: polyester or PVDF; Cloud White standard
- Roof category designation: 50/80 mm
Specifications
Values recorded for 50 mm and items still open
The R-value is the 50 mm core divided by λ = 0.023 W/m·K, and the U-value is its inverse. Neither includes surface resistances or the effect of fixings and laps, so the roof's design U-value should come from the project's own calculation. Profile dimensions, spans and weight are still to be supplied by Jawdah.
| Property | Value |
|---|---|
| Core thickness | 50 mm |
| Insulation core | PIR, λ = 0.023 W/m·K (calculation basis) |
| R-value (core only) | 2.17 m²·K/W |
| U-value (core only) | 0.46 W/m²·K |
| Profile | High rib, 3 ribs per panel width |
| Internal face | Semi-corrugated or plain |
| Cover width, rib height and spacing | Not specified in the supplied data sheet |
| Span, load and panel weight | Not specified in the supplied data sheet |
Comparison
50 mm against the other 3-rib thicknesses
Within the three-rib range, 50 mm sits one step above the 30 mm panel (U 0.77) and one below the 75 mm panel (U 0.31). If the project's energy model asks for a lower roof U-value than 0.46 W/m²·K, move up the table.
| Core thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 30 mm | 1.30 | 0.77 |
| 50 mm | 2.17 | 0.46 |
| 75 mm | 3.26 | 0.31 |
| 100 mm | 4.35 | 0.23 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts
- Jawdah lists a 50 mm core thickness of its 3-rib high-rib PIR roof sandwich panel.
- The 50 mm 3-rib panel has a core R-value of 2.17 m²·K/W and a U-value of 0.46 W/m²·K in Jawdah's data sheet.
- From 30 mm to 50 mm the 3-rib core U-value drops from 0.77 to 0.46 W/m²·K.
- 50 mm is a common middle thickness for ventilated warehouses and factory roofs (general guidance).
- The 5-rib 50 mm panel has the same core values; the profiles differ in rib pattern and span data.
RFQ / BOQ checklist
- Profile and thickness: 3-rib, 50 mm
- Roof area, slope and purlin spacing
- Wind exposure and maintenance traffic
- External facing, coating and colour
- Internal face: semi-corrugated or plain
- Panel lengths and quantities
- Matching ridge, eave and gable flashings and fillers
- Project location and delivery date
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
The 3-rib data sheets give R 2.17 m²·K/W and U 0.46 W/m²·K for the 50 mm core, calculated from λ = 0.023 W/m·K. They exclude surface resistances and thermal bridging.
It is a common middle choice for ventilated or lightly cooled warehouses. Whether it is right depends on the project's thermal target; air-conditioned or cold buildings usually need 75 mm or more.
The core U-value falls from 0.77 to 0.46 W/m²·K, so markedly less heat passes through the roof core. Weight and panel depth increase slightly; Jawdah confirms both per project.
The roof category page uses the pair 50/80 mm. The data sheets calculate from the 50 mm core. Jawdah confirms the overall rib depth for detailing.
Jawdah roof panels are offered with polyester or PVDF coating on PPGI, aluminium, stainless steel or galvanised iron facings. Specify the coating and colour in the request.
Semi-corrugated or plain, as for all Jawdah roof panels. The internal face becomes the visible ceiling of the building.

Next step
Get a quotation for 50 mm 3-rib panels