3-Rib Roof Panels · 75 mm
3-Ribs Roof Sandwich Panels — 75 mm
The 75 mm 3-rib roof panel is the upper-middle thickness of Jawdah's three-rib PIR roof range, aimed at large roofs over spaces that are cooled or occupied for long hours.
- Profile
- High rib, 3 ribs
- Core thickness
- 75 mm
- R-value (core)
- 3.26 m²·K/W
- U-value (core)
- 0.31 W/m²·K

Overview
Quick answer
Jawdah's 75 mm 3-rib roof panel is a high-rib PIR sandwich panel whose 75 mm core gives R 3.26 m²·K/W and U 0.31 W/m²·K in Jawdah's data sheet. It suits large roofs over cooled warehouses, hangars and work halls where the roof must limit heat gain for long hours. Three-rib spans, rib geometry and weight are confirmed by Jawdah per project.
Overview
Why a 75 mm core on a three-rib roof
Its 75 mm core reaches R 3.26 m²·K/W and U 0.31 W/m²·K in the 3-rib data sheets.
This page explains when the deeper core over the 50 mm panel is worth it, how 75 mm compares with the 100 mm panel, and what to send Jawdah. For the profile itself, see the 3-Rib Roof Sandwich Panels page.
The 75 mm panel combines the bold three-rib outer sheet, with its deep ribs and wide drainage troughs, with a PIR core half as deep again as the 50 mm version. The inner face, semi-corrugated or plain, becomes the ceiling of the hall below, so the panel closes, insulates and lines a large roof in one operation.
On a big roof the area is so large that each step in insulation has a real effect on the cooling load. At 75 mm the core U-value falls to 0.31 W/m²·K, against 0.46 at 50 mm. That puts this panel in the range commonly chosen for buildings that are cooled, or where people work under the roof through the hot season, while it remains lighter and shallower than the 100 mm option.
Types
75 mm three-rib or five-rib
At 75 mm the 5-rib panel has the same R 3.26 and U 0.31, since the values depend on the core. Three ribs suit long hangar and warehouse roofs where wide troughs and a strong roof line matter; five ribs suit roofs where a finer pattern or a visible soffit is wanted.
| Aspect | 3-rib, 75 mm | 5-rib, 75 mm |
|---|---|---|
| Core R-value (m²·K/W) | 3.26 | 3.26 |
| Core U-value (W/m²·K) | 0.31 | 0.31 |
| Rib pattern | Bold, widely spaced | Finer, closely spaced |
| Troughs | Wide | Narrower |
| Geometry and spans | Confirmed per project | Confirmed per project |
Pattern and trough rows are general guidance on rib count, not Jawdah measurements.
Applications
Large roofs suited to 75 mm three-rib panels
Jawdah lists hangars, temperature-controlled facilities, warehouses and factories among its roof uses. As general guidance, a 75 mm core is often the point where a three-rib roof is specified for spaces that are actively cooled but not refrigerated.
- Aircraft and equipment hangars
- Cooled warehouses and distribution centres
- Production halls with long working hours
- Large commercial buildings with conditioned interiors
Choosing
Steps before ordering 75 mm 3-rib panels
Confirm that a core U-value of 0.31 W/m²·K meets the roof target in the project's thermal calculation. Then send Jawdah the roof plan, slope, purlin spacing, wind exposure and panel lengths, and ask for three-rib span data at 75 mm, the panel weight, and fillers and flashings for the eaves, ridge and gables.
The roof category page lists this thickness as 75/105 mm, while the data sheets work from the 75 mm core; ask Jawdah to confirm the depth at the ribs for your drawings.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
75 mm 3-rib panel: what the data sheets record
The 75 mm row appears with the values shown below in Jawdah's data sheet. The family facts listed below are taken from the parent roof pages.
- Core thickness: 75 mm, 3-rib high-rib profile
- Thermal row: R 3.26 m²·K/W, U 0.31 W/m²·K (core only)
- Insulation core: PIR; DIN 4102 B2 stated for the core material
- Internal face: semi-corrugated or plain
- Facings: PPGI, aluminium, stainless steel or galvanised iron
- Coating: polyester or PVDF; Cloud White standard
- Roof category designation: 75/105 mm
Specifications
Thermal values and pending geometry at 75 mm
Both values come from the data sheets' method: R is the 75 mm core divided by λ = 0.023 W/m·K and U is its inverse. They describe the insulation core only, without surface resistances or thermal bridges at fasteners and laps. Rib dimensions, span and panel weight at 75 mm remain to be confirmed.
| Property | Value |
|---|---|
| Core thickness | 75 mm |
| Insulation core | PIR, λ = 0.023 W/m·K (calculation basis) |
| R-value (core only) | 3.26 m²·K/W |
| U-value (core only) | 0.31 W/m²·K |
| Profile | High rib, 3 ribs per panel width |
| Internal face | Semi-corrugated or plain |
| Cover width, rib height and spacing | Not specified in the supplied data sheet |
| Span, load and panel weight | Not specified in the supplied data sheet |
Comparison
Placing 75 mm in the 3-rib table
Compared with the 50 mm panel, 75 mm lowers the core U-value from 0.46 to 0.31 W/m²·K; the 100 mm panel goes further, to 0.23. If the energy model is close to its limit at 75 mm, check 100 mm before deciding.
| Core thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 30 mm | 1.30 | 0.77 |
| 50 mm | 2.17 | 0.46 |
| 75 mm | 3.26 | 0.31 |
| 100 mm | 4.35 | 0.23 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts
- Jawdah lists a 75 mm core thickness of its 3-rib high-rib PIR roof sandwich panel.
- The 75 mm 3-rib panel has a core R-value of 3.26 m²·K/W and a U-value of 0.31 W/m²·K (Jawdah's data sheet).
- 75 mm sits between the 50 mm (U 0.46) and 100 mm (U 0.23) 3-rib panels.
- 75 mm three-rib panels are a typical choice for cooled warehouses and hangars (general guidance).
- Three-rib span data, rib geometry and weight at 75 mm are confirmed by Jawdah per project.
RFQ / BOQ checklist
- Profile and thickness: 3-rib, 75 mm
- Roof area, slope and purlin spacing
- Wind exposure and maintenance traffic
- External facing, coating and colour
- Internal face: semi-corrugated or plain
- Panel lengths and quantities
- Matching ridge, eave and gable flashings and fillers
- Project location and delivery date
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
Jawdah's 3-rib data sheets give R 3.26 m²·K/W and U 0.31 W/m²·K for the 75 mm core, calculated from λ = 0.023 W/m·K and excluding surface resistances.
When the roof covers a cooled space or one occupied for long hours and the energy target needs a core U-value below 0.46 W/m²·K. 75 mm brings it to 0.31.
Hangars are among Jawdah's listed roof applications, and a 75 mm three-rib panel is a typical choice where the hangar is cooled. Confirm spans for the purlin layout with Jawdah.
Cold stores usually need the thickest insulation available. Review 100 mm, or 150 mm whose value Jawdah confirms on request, against the cold store's design temperature.
It is the paired designation used on the roof category page for this thickness. The data sheets calculate from the 75 mm core; Jawdah confirms the overall depth at the ribs.
Yes. Both data sheets give R 3.26 m²·K/W and U 0.31 W/m²·K at 75 mm. Rib pattern, trough width and span data are what set them apart.

Next step
Specify 75 mm 3-rib roof panels
Send the roof plan, slope, purlin spacing and thermal target. Jawdah will confirm 75 mm three-rib spans, fillers, flashings and a quotation.




