Jawdah Industrial Co. Ltd.

3-Rib Roof Panels · 100 mm

3-Ribs Roof Sandwich Panels — 100 mm

The 100 mm 3-rib roof panel is the thickest three-rib panel with published thermal values in Jawdah's PIR roof range, built for roofs that must hold heat out of temperature-controlled buildings.

Profile
High rib, 3 ribs
Core thickness
100 mm
R-value (core)
4.35 m²·K/W
U-value (core)
0.23 W/m²·K
3-Ribs Roof Sandwich Panels 100 mm

Overview

Quick answer

Jawdah's 100 mm 3-rib roof panel has a 100 mm PIR core under a three-rib high-rib sheet. Jawdah's data sheet gives it R 4.35 m²·K/W and U 0.23 W/m²·K, the lowest roof U-value Jawdah publishes. It is intended for temperature-controlled facilities and other buildings where the roof heat load must be kept low. Spans, weight and rib geometry are confirmed per project.

Overview

The 100 mm three-rib panel and what it is for

Its 100 mm core gives R 4.35 m²·K/W and U 0.23 W/m²·K.

This page covers where that level of insulation is needed, what a deeper panel changes on site, and how 100 mm compares with the 75 mm panel and the 150 mm panel. The profile is described on the 3-Rib Roof Sandwich Panels page.

With a 100 mm polyisocyanurate core, this panel is the deepest three-rib roof panel whose thermal values Jawdah publishes. The high-rib outer sheet with its three deep ribs handles water and spans between purlins; the semi-corrugated or plain inner sheet forms a clean ceiling over the conditioned space.

The thicker core cuts heat flow through the roof to a core U-value of 0.23 W/m²·K, against 0.77 at 30 mm. On a hot Saudi roof this is the panel to examine first when a building is kept cool around the clock, when stored goods are temperature-sensitive, or when the energy model is tight. In return the panel is heavier and deeper than the thinner options, which affects fasteners, flashings and handling.

Types

Three-rib or five-rib at 100 mm

The 5-rib 100 mm panel gives the same R 4.35 and U 0.23. For long temperature-controlled warehouse roofs, the three-rib profile's wide troughs and bold line are often the practical choice; five ribs are preferred where a finer surface or a visible soffit is part of the design.

3-rib and 5-rib at 100 mm
Aspect3-rib, 100 mm5-rib, 100 mm
Core R-value (m²·K/W)4.354.35
Core U-value (W/m²·K)0.230.23
Rib patternBold, widely spacedFiner, closely spaced
TroughsWideNarrower
Geometry and spansConfirmed per projectConfirmed per project

Pattern and trough rows are general guidance on rib count, not Jawdah measurements.

Applications

Buildings that call for a 100 mm three-rib roof

Jawdah names temperature-controlled facilities among its roof applications, alongside warehouses, factories and commercial facilities. As general guidance, the 100 mm three-rib panel fits large roofs where cooling runs continuously or where goods are kept within a temperature band.

  • Temperature-controlled warehouses and logistics hubs
  • Food, pharmaceutical and packaging storage
  • Air-conditioned factories and assembly halls
  • Large roofs where the energy model is tight

Choosing

Before ordering 100 mm 3-rib panels

Check the roof target against U 0.23 W/m²·K in the project's thermal calculation, adding surface resistances and bridging. Send Jawdah the roof plan, slope, purlin spacing, wind exposure and lengths, and ask for the three-rib span at 100 mm, the panel weight, fastener length, and fillers and flashings sized for the deeper panel.

The roof category page shows this thickness as 100/130 mm; the data sheets calculate from the 100 mm core. Confirm the depth at the ribs before detailing ridges and eaves.

Technical

Closer look

Detailed product imagery is being prepared.

In preparation

Jawdah data

Recorded facts for the 100 mm 3-rib panel

In Jawdah's data sheet, 100 mm is the deepest 3-rib thickness with a confirmed thermal value.

  • Core thickness: 100 mm, 3-rib high-rib profile
  • Thermal row: R 4.35 m²·K/W, U 0.23 W/m²·K (core only)
  • Insulation core: PIR; DIN 4102 B2 stated for the core material
  • Internal face: semi-corrugated or plain
  • Facings: PPGI, aluminium, stainless steel or galvanised iron
  • Coating: polyester or PVDF; Cloud White standard
  • Roof category designation: 100/130 mm

Specifications

100 mm values and the data still missing

R is the 100 mm core divided by λ = 0.023 W/m·K and U is its inverse. These are core-only values; surface resistances and thermal bridging through fasteners and laps are not included. The data sheets supplied do not state the panel weight, rib dimensions or span at 100 mm.

3-rib roof panel, 100 mm: Jawdah data-sheet values
PropertyValue
Core thickness100 mm
Insulation corePIR, λ = 0.023 W/m·K (calculation basis)
R-value (core only)4.35 m²·K/W
U-value (core only)0.23 W/m²·K
ProfileHigh rib, 3 ribs per panel width
Internal faceSemi-corrugated or plain
Cover width, rib height and spacingNot specified in the supplied data sheet
Span, load and panel weightNot specified in the supplied data sheet

Comparison

Where 100 mm stands among 3-rib thicknesses

From the 75 mm panel to 100 mm the core U-value drops from 0.31 to 0.23 W/m²·K. The deeper 3-rib panel in the dimension table has no published value yet; Jawdah confirms it on request.

3-rib roof panel thicknesses (Jawdah data sheet)
Core thicknessR-value (m²·K/W)U-value (W/m²·K)
30 mm1.300.77
50 mm2.170.46
75 mm3.260.31
100 mm4.350.23

Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts

  1. Jawdah lists a 100 mm core thickness of its 3-rib high-rib PIR roof sandwich panel.
  2. The 100 mm 3-rib panel has a core R-value of 4.35 m²·K/W and a U-value of 0.23 W/m²·K, the lowest roof U-value Jawdah publishes.
  3. Jawdah's 3-rib data sheet publishes thermal values for 30, 50, 75 and 100 mm; 100 mm is the deepest of these.
  4. The 100 mm three-rib panel suits temperature-controlled warehouses and air-conditioned factories (general guidance).
  5. Weight, rib geometry and spans of the 100 mm 3-rib panel are confirmed by Jawdah per project.

RFQ / BOQ checklist

  • Profile and thickness: 3-rib, 100 mm
  • Roof area, slope and purlin spacing
  • Wind exposure and maintenance traffic
  • External facing, coating and colour
  • Internal face: semi-corrugated or plain
  • Panel lengths and quantities
  • Matching ridge, eave and gable flashings and fillers
  • Project location and delivery date

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • 0.23 W/m²·K for the core, with an R-value of 4.35 m²·K/W, according to Jawdah's data sheet. Both exclude surface resistances and thermal bridging.

  • It has the lowest roof U-value Jawdah publishes. A deeper thickness is also listed; Jawdah confirms its value on request.

  • Typically temperature-controlled warehouses, storage for temperature-sensitive goods and air-conditioned factories with large roofs, where the roof heat load must be kept low.

  • Fasteners must suit the full panel depth, and ridge, eave and gable flashings and fillers must be sized for it. Jawdah confirms these for the 100 mm three-rib panel per project.

  • The roof category page uses it as the paired name for this thickness. The data sheets calculate from the 100 mm core; ask Jawdah for the overall depth at the ribs.

  • Yes, a deeper core adds weight. The exact weight is not in the supplied data sheet; Jawdah confirms it with the facing thickness for your project.

Next step

Plan a 100 mm 3-rib roof with Jawdah

Send the roof plan, slope, purlin spacing and thermal target. Jawdah will confirm spans, fixings, flashings and a quotation for 100 mm three-rib panels.