3-Rib Roof Panels · 30 mm
3-Ribs Roof Sandwich Panels — 30 mm
The 30 mm 3-rib roof panel is the thinnest panel in Jawdah's three-rib high-rib PIR roof range, with a 30 mm PIR core under a boldly ribbed outer sheet.
- Profile
- High rib, 3 ribs
- Core thickness
- 30 mm
- R-value (core)
- 1.30 m²·K/W
- U-value (core)
- 0.77 W/m²·K

Overview
Quick answer
The Jawdah 3-rib roof panel in 30 mm is a high-rib PIR sandwich panel whose data sheet from Jawdah gives a core R-value of 1.30 m²·K/W and a U-value of 0.77 W/m²·K. It is the thinnest and least insulating 3-rib option, suited to roofs where heat gain matters little. Rib geometry, spans and weight are confirmed by Jawdah per project.
Overview
What the 30 mm 3-rib roof panel is
Its data sheets give it a core R-value of 1.30 m²·K/W and a U-value of 0.77 W/m²·K, the highest heat flow of the range.
This page shows where so little insulation is enough, how 30 mm compares with the thicker 50 mm 3-rib panel, and what to send Jawdah. The profile itself is described on the 3-Rib Roof Sandwich Panels page.
The panel is a factory-made roof element: a 30 mm rigid PIR insulation core bonded between a high-rib outer sheet with three raised ribs across its width and an inner sheet that is semi-corrugated or plain. Fixed straight onto purlins, it forms the weather skin, the insulation and the visible ceiling in one lift.
Thirty millimetres is the smallest core depth Jawdah lists for this profile. The thin core keeps the panel light and the roof build-up shallow, but it also lets the most heat through: a U-value of 0.77 W/m²·K, against 0.23 W/m²·K at 100 mm. That makes the 30 mm panel a choice for buildings where the roof has to shed rain and take the edge off solar heat, rather than hold a controlled temperature inside.
Types
30 mm in 3 ribs or 5 ribs
At 30 mm the thermal values are the same for both profiles, because they depend on the core alone. The choice between three ribs and the 5-rib 30 mm panel is therefore about the roof: three ribs give a bold line and wide troughs for long industrial runs, five ribs a finer pattern often preferred on canopies seen from below.
| Aspect | 3-rib, 30 mm | 5-rib, 30 mm |
|---|---|---|
| Core R-value (m²·K/W) | 1.30 | 1.30 |
| Core U-value (W/m²·K) | 0.77 | 0.77 |
| Rib pattern | Bold, widely spaced | Finer, closely spaced |
| Troughs | Wide | Narrower |
| Geometry and spans | Confirmed per project | Confirmed per project |
Pattern and trough rows are general guidance on rib count, not Jawdah measurements.
Applications
Roofs where 30 mm is enough
Jawdah lists its roof panels for industrial roofs, warehouses, factories, hangars, pre-manufactured buildings and commercial facilities. Within that list, the thinnest 3-rib panel fits where the space below is open, ventilated or used only part of the time. As general guidance:
- Workshops and maintenance sheds without air conditioning
- Pre-manufactured site buildings and temporary structures
- Open-sided storage and loading roofs
- Agricultural and equipment shelters
Choosing
Before you order 30 mm 3-rib panels
Check the thermal target first: if a roof U-value of 0.77 W/m²·K meets it, the 30 mm panel gives the lightest 3-rib roof. Then send Jawdah the purlin spacing, slope, wind exposure and panel lengths so it can confirm three-rib spans, weight and fillers at this thickness.
The roof category page lists this thickness as 30/60 mm, while Jawdah's data sheet calculates the values from the 30 mm core. Ask Jawdah to confirm the overall depth at the ribs for your order.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
What Jawdah's data states for the 30 mm 3-rib panel
Jawdah's 3-rib data sheet lists a 30 mm row with the thermal values shown below. The family facts below come from the parent roof pages and apply because the panel belongs to the same high-rib PIR roof range.
- Core thickness: 30 mm, 3-rib high-rib profile
- Thermal row: R 1.30 m²·K/W, U 0.77 W/m²·K (core only)
- Insulation core: PIR; DIN 4102 B2 stated for the core material
- Internal face: semi-corrugated or plain
- Facings: PPGI, aluminium, stainless steel or galvanised iron
- Coating: polyester or PVDF; Cloud White standard
- Roof category designation: 30/60 mm
Specifications
30 mm 3-rib panel values and open items
The thermal values are calculated, not measured: R equals the 30 mm core thickness divided by the PIR conductivity of 0.023 W/m·K, and U is its inverse. They exclude surface resistances and thermal bridging, so a full roof calculation gives a different figure. Geometry, span and weight are not in the supplied data.
| Property | Value |
|---|---|
| Core thickness | 30 mm |
| Insulation core | PIR, λ = 0.023 W/m·K (calculation basis) |
| R-value (core only) | 1.30 m²·K/W |
| U-value (core only) | 0.77 W/m²·K |
| Profile | High rib, 3 ribs per panel width |
| Internal face | Semi-corrugated or plain |
| Cover width, rib height and spacing | Not specified in the supplied data sheet |
| Span, load and panel weight | Not specified in the supplied data sheet |
Comparison
How 30 mm sits in the 3-rib thickness range
| Core thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 30 mm | 1.30 | 0.77 |
| 50 mm | 2.17 | 0.46 |
| 75 mm | 3.26 | 0.31 |
| 100 mm | 4.35 | 0.23 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Key facts
- Jawdah's 3-rib roof panel is listed in a 30 mm core thickness, the thinnest of 30, 50, 75, 100 and 150 mm.
- At 30 mm the 3-rib panel has a core R-value of 1.30 m²·K/W and a U-value of 0.77 W/m²·K (Jawdah's data sheet).
- The thermal values exclude surface resistances and thermal bridging and are calculated from λ = 0.023 W/m·K.
- The 30 mm 3-rib panel suits roofs where low insulation is acceptable, such as workshops and open-sided structures (general guidance).
- Rib geometry, spans and panel weight of the 30 mm 3-rib panel are confirmed by Jawdah per project.
RFQ / BOQ checklist
- Profile and thickness: 3-rib, 30 mm
- Roof area, slope and purlin spacing
- Wind exposure and maintenance traffic
- External facing, coating and colour
- Internal face: semi-corrugated or plain
- Panel lengths and quantities
- Matching ridge, eave and gable flashings and fillers
- Project location and delivery date
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
Jawdah's 3-rib data sheets give a U-value of 0.77 W/m²·K and an R-value of 1.30 m²·K/W for the 30 mm core. Both are calculated from λ = 0.023 W/m·K and cover the core only.
Usually not on its own. 30 mm is the least insulating 3-rib thickness, and air-conditioned or temperature-controlled buildings normally need the thicker end of the range. Check the project's energy target before choosing.
The roof category page uses paired designations such as 30/60 mm, while the data sheets calculate the values from the 30 mm core. Ask Jawdah to confirm the overall depth at the ribs for your drawings.
Yes for thermal values: both data sheets give R 1.30 m²·K/W and U 0.77 W/m²·K at 30 mm. The profiles differ in rib pattern, trough width and their own span data.
Span data is not in the supplied data sheet. Jawdah confirms the allowable purlin spacing for the 3-rib profile at 30 mm per project, taking wind and maintenance loads into account.
Ridge, eave and gable flashings and profile fillers shaped to the three-rib profile. They are ordered with the panels from the Jawdah roof flashings range.

Next step
Request 30 mm 3-rib roof panels
Send the roof area, slope, purlin spacing and colour. Jawdah will confirm spans, fillers and a quotation for the 30 mm 3-rib panel.