Jawdah Industrial Co. Ltd.

Secret-Fix Wall Panels · 50 mm

Secret-Fix Wall Sandwich Panel — 50 mm

The 50 mm secret-fix wall panel is the thinnest of the three thicknesses in which Jawdah lists its concealed-fix PIR wall sandwich panel.

Thickness
50 mm
R-value (core)
2.17 m²·K/W
U-value (core)
0.46 W/m²·K
Core
Rigid PIR
Secret Fix Wall Sandwich Panels 50 mm

Overview

Quick answer

Jawdah's 50 mm secret-fix wall panel is a PIR-core sandwich panel fixed through its side joint, so no screws show on the face. Its data sheets state R 2.17 m²·K/W and U 0.46 W/m²·K for the core alone. It is the slimmest and lightest option in the secret-fix range, suited to clean-looking walls where the insulation demand is moderate.

Overview

What the 50 mm secret-fix panel is

Jawdah's data sheet gives it an R-value of 2.17 m²·K/W and a U-value of 0.46 W/m²·K. The fixing principle is explained on the secret-fix wall sandwich panel page; this page covers what changes at 50 mm.

This is a factory-made composite panel: a rigid polyisocyanurate (PIR) core bonded between two pre-painted metal facings, with edges shaped so that each panel's fasteners are covered by the next one. At 50 mm it carries the least insulation of the secret-fix thicknesses Jawdah lists, which also makes it the slimmest panel in that range.

The fixing method and facing options are shared with the 75 mm and 100 mm panels. What the thickness decides is how much heat the wall lets through and how deep the finished wall build-up becomes.

Applications

Where a 50 mm secret-fix wall typically fits

As general guidance, the thinnest core in a range is chosen when the wall's appearance matters more than its insulation depth: internal feature walls and partitions inside air-conditioned buildings, showroom and reception enclosures, and façade areas that are shaded or not conditioned behind.

Jawdah does not publish an application list per thickness for the secret-fix panel. Where the building is cooled for long hours or an energy target applies, check the 75 mm and 100 mm panels against the design U-value before settling on 50 mm.

Installation

Fixing and set-out points at 50 mm

Concealed fixing needs straight rails in one plane, because the panel cannot be pulled into line by a face screw. Fastener length and any clip are matched to the 50 mm edge, and the structural engineer sets the fixing schedule from wind exposure and rail spacing using Jawdah's joint data. Trims for corners and openings come from the wall flashings range.

Choosing

Ordering 50 mm secret-fix panels

In the request for quotation, state 50 mm, the facing and coating, colour, panel lengths and quantities, orientation, and the elevations showing the concealed-fix areas. Ask Jawdah for the joint drawing, cover width and fixing schedule, which are not yet published.

If a consultant needs the thermal basis, ask Jawdah for the data sheet that applies to the order.

Technical

Closer look

Detailed product imagery is being prepared.

In preparation

Jawdah data

What Jawdah's data sheets state for 50 mm

Jawdah's data sheet lists the secret-fix wall panel in 50, 75 and 100 mm and gives the thermal values below for 50 mm.

  • Panel thickness: 50 mm, listed on Jawdah's data sheet
  • Insulation core: polyisocyanurate (PIR)
  • Core conductivity used in the calculation: λ = 0.023 W/m·K
  • R-value 2.17 m²·K/W and U-value 0.46 W/m²·K, core only
  • Fixing: concealed in the side joint

Specifications

Thermal performance of the 50 mm secret-fix panel

R is the core thickness divided by the core conductivity, and U is its inverse. In practical terms a U-value of 0.46 W/m²·K means each square metre of core passes about 0.46 watts for every kelvin of temperature difference across it. Surface resistances are excluded and the values are calculated, not measured, so the wall build-up needs its own calculation before the figure is used for compliance.

Secret-fix wall panel 50 mm: thermal values (Jawdah data sheet)
Panel thicknessR-value (m²·K/W)U-value (W/m²·K)
50 mm2.170.46

Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Comparison

50 mm against the other secret-fix thicknesses

The three thicknesses share the core material, fixing principle and facing options; core depth alone changes the thermal values. Moving from 50 mm to 75 mm lowers the U-value by roughly a third, and the 100 mm panel lets through half the heat of the 50 mm panel under the same conditions.

Choose 50 mm when a slimmer wall and lighter panels count for more than extra insulation. The same thickness with a recessed shadow line is the grooved secret-fix 50 mm panel.

Secret-fix wall panel thicknesses compared (Jawdah data sheet)
Panel thicknessR-value (m²·K/W)U-value (W/m²·K)
50 mm (this page)2.170.46
75 mm3.260.31
100 mm4.350.23

Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Materials

Facings and finishes for the 50 mm panel

The Jawdah wall range lists PPGI, aluminium, stainless steel and galvanised iron facings, with polyester or PVDF coating and Cloud White as the standard colour. The supplied data does not list facing options per thickness, so confirm with the Jawdah team which of these are offered in the concealed-fix profile at 50 mm.

Key facts

  1. Jawdah lists its secret-fix PIR wall sandwich panel in 50 mm on its data sheet.
  2. 50 mm secret-fix wall panel: R 2.17 m²·K/W and U 0.46 W/m²·K, core only, calculated from λ = 0.023 W/m·K.
  3. 50 mm is the thinnest of the three secret-fix thicknesses: 50, 75 and 100 mm.
  4. In a secret-fix wall the fasteners sit in the side joint and are covered by the adjoining panel.
  5. The 50 mm secret-fix panel passes twice the core heat flow of the 100 mm panel.
  6. Joint geometry, cover width and fixing schedule of the Jawdah secret-fix panel are confirmed per project.

RFQ / BOQ checklist

  • Panel thickness: 50 mm
  • Facing material and coating (polyester or PVDF)
  • Colour: Cloud White or the required colour
  • Panel lengths and total quantity
  • Orientation: vertical or horizontal
  • Elevations showing the concealed-fix areas and openings
  • Wind exposure and rail spacing for the fixing schedule
  • Corner, opening and base trims required
  • Delivery city and programme

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • Jawdah's data sheets give 0.46 W/m²·K, with an R-value of 2.17 m²·K/W. Both are calculated from the PIR core conductivity of 0.023 W/m·K and describe the core only.

  • Yes. Jawdah's data sheet lists the secret-fix wall panel in 50, 75 and 100 mm, and 50 mm is the thinnest of the three.

  • As general guidance, when the wall is mainly architectural and the insulation demand is moderate, for example internal feature walls or shaded façade areas. A heat-load or energy calculation should confirm it.

  • Its U-value of 0.23 W/m²·K is half the 50 mm value, so under the same conditions half as much heat passes through the core. The 75 mm panel sits between them at 0.31 W/m²·K.

  • The concealed-fix principle is the same at every thickness. Fastener length, clips and the fixing schedule are matched to the panel and confirmed with Jawdah's joint data.

  • No. Joint geometry, cover width and the fixing schedule are not in the supplied data and are confirmed by the Jawdah team for each project.

  • No. They are calculated for the PIR core alone, without surface resistances or thermal bridging, so a complete wall calculation will give a different figure.

Next step

Request 50 mm secret-fix wall panels

Send the thickness, facing, colour, lengths and quantities with your elevations. The Jawdah team will confirm the joint details, the applicable data sheet and a project quotation.