Wall Flashings · WF-102
WF-102 Internal Wall Flashing for Sandwich Panel Walls
WF-102 Internal Wall Flashing is the coded Jawdah wall flashing for inside corners, where two sandwich panel walls meet at an angle that faces into a room, a recess or a courtyard.
- Code
- WF-102
- Position
- Inside wall corner
- Dimensions
- Confirmed per project

Overview
Quick answer
WF-102 Internal Wall Flashing is a formed metal trim for the inside corner of sandwich panel walls, seen from the room side or from inside a recess. It covers the panel edges at the corner joint and gives a neat, cleanable angle, which matters most in cold rooms and food areas. Jawdah confirms its profile, colour and quantity per project.
Overview
Why inside corners get their own trim
It closes the panel edges in the corner, hides the joint and leaves a clean angle that is easy to inspect and wipe down.
WF-102 is the second item of the Jawdah Wall Flashings range. Its profile, gauge, material and lengths are not published and are confirmed per project, so this page focuses on where WF-102 goes, why inside corners need their own trim and what to send for pricing.
An inside corner looks simpler than an outside one, but the two panels still meet with cut edges and an interrupted joint. Left open, the gap collects dust, hides moisture and breaks the hygiene line of a room. WF-102 Internal Wall Flashing closes that angle. Its legs lie on both panel faces inside the corner, covering the edges and the gap between them.
Inside corners appear in two places on a panel building. Most are on the room side of the walls: every corner of a cold store, a clean production room or a partitioned office in panels. Others are on the outside, where the façade steps inward around a recess or an entrance bay.
Jawdah pairs WF-102 with WF-101 External Wall Flashing, which covers the outward-facing corner. The exact WF-102 section is confirmed by Jawdah for each project.
How it works
How an internal corner trim seats
As general guidance, an inside corner trim has two legs that meet at the corner angle and press flat onto each panel face. Because the angle faces inward, the trim is pushed into the corner rather than wrapped around it, so the panels must be fixed square before it goes on. Sealant or strip sealant behind the legs closes any remaining gap, which matters on cold room walls where air leaks carry moisture into the joint.
Types
WF-102 compared with the other wall flashing codes
The decision between WF-101 and WF-102 is simply which way the corner faces. The other codes are not corner trims.
| Code | Corner or edge | Seen from | Choose it when |
|---|---|---|---|
| WF-101 | Outside corner | The street or yard | The wall turns outward |
| WF-102 | Inside corner | The room or a recess | The angle faces inward |
| WF-103 | Step between planes | Outside | One face must lap over another |
| WF-104 | Free edge | Either side | A panel end needs a channel |
| WF-105 | Drip edge | Outside | Water must drop clear of the wall |
Applications
Where WF-102 is used
Typical inside-corner positions on Jawdah panel buildings include:
- Room-side corners of cold rooms and chillers
- Inside corners of food, pharmaceutical and clean production rooms
- Partition-to-external-wall junctions inside panel buildings
- Recessed entrance bays and stepped façades
- Inside corners of fire rated panel enclosures, detailed with the wall system
Selection pitfalls
Inside-corner mistakes to avoid
Inside corners are small, so they are easy to leave until the end and get wrong.
- Matching WF-102 to the outside colour when the room-side facing differs
- Leaving the corner open in cold rooms, so air and moisture enter the joint
- Fitting the trim before the panels are square, leaving a gap on one leg
- Using an outside-corner trim reversed instead of an inside-corner one
Choosing
Ordering WF-102
Mark every inward-facing corner on plans and elevations as WF-102 and give its height. List room-side and outside corners separately, because they may need different colours. The trim is quoted with the Wall Flashings package; for cold rooms, send the Cold Room Wall Panel layout with it.
Technical
Closer look

Materials
Materials and hygiene on the room side
Jawdah wall panels are faced with PPGI, aluminium, stainless steel or galvanised iron with polyester or PVDF coating, standard Cloud White (RAL 9002). The room-side face of a cold room is often different from the outside face, so state which facing WF-102 must match. For rooms that are washed down, ask for a corner detail without ledges where water or dirt can sit, and confirm the trim material with Jawdah.
Specifications
WF-102 data status
No technical data sheet covers Jawdah flashings, so the WF-102 values below are confirmed in the quotation.
| Property | Value |
|---|---|
| Code and name | WF-102 Internal Wall Flashing |
| Range | Wall Flashings |
| Leg sizes and girth | Not specified in the supplied data sheet |
| Sheet material and thickness | Not specified in the supplied data sheet |
| Colour | Confirmed per project, matched to the facing it meets |

Key facts
- WF-102 Internal Wall Flashing is a coded item in the Jawdah Wall Flashings range.
- WF-102 closes inside corners of sandwich panel walls, mostly on the room side.
- WF-102 is the inside-corner counterpart of WF-101 External Wall Flashing.
- Cold room inside corners are sealed to keep air, moisture and dirt out of the joint.
- Jawdah confirms WF-102 dimensions, material and colour per project.
RFQ / BOQ checklist
- Plans and elevations with inside corners marked WF-102
- Height of each corner, room-side and outside listed separately
- Panel type and thickness at each corner
- Facing and colour WF-102 must match
- Hygiene or wash-down requirements for the rooms
- Delivery with the panel package or separately
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
A coded Jawdah trim that closes the inside corner where two sandwich panel walls meet at an angle facing into a room or recess.
Mostly on the room side, but it also suits outside corners that face inward, such as a recessed entrance bay in a panel façade.
An open corner joint lets air and moisture into the panel edge and collects dirt. A sealed corner trim keeps the joint closed and the room easier to clean.
The face it covers. Room-side corners match the internal facing, recess corners match the external one, so list them separately in the RFQ.
No. Jawdah confirms the leg sizes, sheet thickness, material and lengths of WF-102 per project.
WF-101 covers outward-facing corners; WF-102 sits inside inward-facing corners. The choice depends only on which way the corner faces.

Next step
Get WF-102 quoted with your panel rooms
Send the room layout and elevations with inside corners marked. The Jawdah team will confirm the WF-102 profile, colour and quantity with the panels.




