Wall Flashings · WF-103
WF-103 Z-Angle Flashing for Sandwich Panel Walls
WF-103 Z-Angle is the coded Jawdah wall flashing with a Z-shaped section, used where a sandwich panel wall must step from one plane to another or where one surface has to lap over the surface below.
- Code
- WF-103
- Section
- Z-shaped
- Dimensions
- Confirmed per project

Overview
Quick answer
WF-103 Z-Angle is a Z-shaped metal flashing for sandwich panel walls. One flange is held by the upper element, the web crosses the joint and the other flange laps over the face below, so water is carried outward across a horizontal joint or change of plane. Jawdah confirms the WF-103 section, material and lengths per project.
Overview
What a Z-angle flashing solves
Its two flanges point in opposite directions, so one can sit behind or on top of the upper element while the other projects over the face beneath it.
WF-103 is the third code in the Jawdah Wall Flashings range. Its flange sizes, offset, gauge and material are not published; this page explains the Z principle, the positions it usually serves and the details Jawdah needs to confirm a WF-103 profile.
Corner trims close vertical edges. Many leaks on panel walls start instead at horizontal lines: where a panel wall sits on a masonry upstand, where the façade steps back, where panels meet a different cladding, or where one row of panels ends above another. Water running down the upper surface must cross that line without being led behind it.
A Z-angle does this with geometry rather than sealant. One flange is held behind or on the upper element, the middle web spans the joint, and the lower flange projects over the outer face of the element below. Water coming down meets the web and is turned outward over the lower flange.
In Jawdah's coding this is WF-103 Z-Angle. It is a step-and-lap trim, not a corner trim, which is the main difference from WF-101 External Wall Flashing and WF-102. Jawdah confirms its section for each detail.
Construction
Parts of a Z section
As general guidance, a Z flashing is read in three parts. Their sizes for WF-103 are confirmed by Jawdah.
- Upper flange: held behind, under or on the upper element
- Web: crosses the joint and sets the offset between the two planes
- Lower flange: laps over the face below and sheds water outward
- Hem or drip: an optional turned edge on the lower flange, confirmed per detail
Types
Z-angle or another wall flashing code?
WF-103 overlaps with two siblings at first glance. The table separates them.
| Situation | Usual code | Why |
|---|---|---|
| Horizontal step or change of plane | WF-103 Z-Angle | The offset web carries water from one plane to the next |
| Bottom edge where water must drop clear | WF-105 Drip Trim | A drip edge breaks the water film below the wall |
| Free panel end needing a cap | WF-104 U-Channel | The channel wraps the end of the panel |
| Outside corner | WF-101 External Wall Flashing | Covers two vertical edges at a corner |
Applications
Typical WF-103 positions on a panel wall
Common Z-angle positions include the line where a panel wall starts above a concrete or block upstand, a horizontal joint between panel rows, the step where a façade sets back, and the junction between panels and another cladding. On concealed-fix walls such as the Secret-Fix Wall Panel, where no fasteners show on the face, the Z-angle is detailed so its fixings sit in the joint or behind the upper element.
Installation
Fitting a Z-angle
Fix the lower element first, then the Z-angle, then the upper element, so each upper part laps the one below. Seal the upper flange where the detail requires it, join lengths with a lap in the direction water flows, and keep the lower flange level so water does not run along it to one end.
Selection pitfalls
Z-angle errors
Z-angles fail when the offset or the lap direction is wrong.
- Offset too small, so the lower flange sits flush instead of projecting
- Upper flange fixed in front of the upper element instead of behind it
- Sloping lower flange that channels water to one end
- Exposed fasteners added to a concealed-fix façade
Choosing
Specifying WF-103
Draw each horizontal step or plane change as a section with the panel and the element below, mark it WF-103 and give its running length. Send these sections with the Wall Flashings list; where the line also needs a drip, compare with WF-105 Drip Trim.
Technical
Closer look


Specifications
WF-103 data status
No technical data sheet is available for Jawdah flashings; the WF-103 values below are confirmed in the quotation.
| Property | Value |
|---|---|
| Code and name | WF-103 Z-Angle |
| Range | Wall Flashings |
| Flange sizes and offset | Not specified in the supplied data sheet |
| Material and thickness | Not specified in the supplied data sheet |
| Colour | Confirmed per project |

Key facts
- WF-103 Z-Angle is a coded item in the Jawdah Wall Flashings range.
- A Z-angle steps water across a horizontal joint or change of plane on a panel wall.
- The Z section has an upper flange, a web and a lower flange that laps over the face below.
- WF-103 is not a corner trim; WF-101 and WF-102 close corners.
- Jawdah confirms WF-103 flange sizes, material and colour per project.
RFQ / BOQ checklist
- Sections of every step or horizontal joint marked WF-103
- Running length per section type
- Element below the step: panel, masonry or other cladding
- Wall panel type: through-fixed or concealed-fix
- Colour and facing to match
- Delivery with the panel package or separately
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
It carries water across a horizontal joint or a change of plane on a sandwich panel wall, lapping the upper element over the face below.
Its section has two flanges pointing in opposite directions joined by a web, which looks like the letter Z.
No. WF-101 and WF-102 close corners. WF-103 works along horizontal lines and steps between planes.
Yes, as a general detail, provided its fixings are hidden in the joint or behind the upper element so the face stays clear.
Jawdah has not published WF-103 flange sizes, offset or thickness. They are confirmed per project from your section drawings.
Sections of each step or joint, running lengths, panel type and colour, together with the wall panel RFQ.

Next step
Send your Z-angle sections
Share the wall sections where planes step or joints run horizontally. The Jawdah team will confirm the WF-103 profile and quantities with the panels.