Jawdah Industrial Co. Ltd.

Cold Room Wall Panels · 150 mm

Cold Room Wall Sandwich Panel — 150 mm

The 150 mm cold room wall panel is a deep-core PIR panel in Jawdah's cold room range; Jawdah confirms its thermal values with the quotation.

Thickness
150 mm
R-value (core)
Confirmed by Jawdah on request
U-value (core)
Confirmed by Jawdah on request
Core
Rigid PIR
Cold Room Wall Sandwich Panels 150 mm

Overview

Quick answer

Jawdah's 150 mm cold room wall panel is a PIR-core sandwich panel for rooms that need deep insulation. Jawdah lists this thickness and confirms its thermal values with the quotation, so confirm availability and values with Jawdah when ordering.

Overview

What the 150 mm cold room panel is

Jawdah lists the 150 mm thickness in its cold room range and confirms its thermal values with the quotation; availability is confirmed per order. See the cold room wall sandwich panel page for room design basics.

It is a cold room wall element with a 150 mm rigid PIR core between two metal facings, half again as deep as the 100 mm panel. The deeper core is there to cut heat gain into rooms where the temperature difference across the wall is large or the refrigeration load must be kept low.

Availability of this thickness is confirmed with each order.

Performance

Details for a 150 mm cold room

At this depth the panel itself lets little heat through, so joints, the floor and openings decide the result. As general practice for low-temperature rooms, insulate the floor or provide a thermal break at the base, seal every joint and corner continuously, sleeve penetrations, and coordinate doors, pressure relief and lighting with the panel layout. Trims come from the wall flashings range.

Applications

Where a 150 mm cold room wall typically fits

As general guidance, a 150 mm core is considered for rooms with a large temperature difference to their surroundings, such as frozen storage, or for rooms exposed to outdoor heat rather than sheltered in a hall. Jawdah does not publish set points per thickness, so the refrigeration heat-load calculation should show that 150 mm is needed.

If the calculation is met at 100 mm, the 100 mm panel has values on Jawdah's data sheet; if it asks for more, compare the 200 mm panel.

Choosing

Ordering 150 mm cold room panels

Ask Jawdah first to confirm that 150 mm is available and which data sheet applies, then send room sizes, set temperature, surroundings, heat-load result, faces, ceiling and floor details, doors and quantities.

Technical

Closer look

Detailed product imagery is being prepared.

In preparation

Jawdah data

What Jawdah lists for 150 mm

Jawdah lists the cold room wall panel in 50, 75, 100, 150 and 200 mm. For 150 mm, Jawdah confirms the thermal values with the quotation.

  • Thickness: 150 mm
  • Core: rigid PIR
  • R- and U-values: confirmed by Jawdah with the quotation
  • Range: 50, 75, 100, 150 and 200 mm
  • Availability: confirmed by Jawdah per order

Specifications

Thermal values of the 150 mm cold room panel

Jawdah confirms the R- and U-values of the 150 mm panel with the quotation. As for the thinner panels, the values cover the insulation core only and exclude surface resistances and thermal bridging.

Cold room wall panel 150 mm: thermal values
Panel thicknessR-value (m²·K/W)U-value (W/m²·K)
150 mmConfirmed by Jawdah on requestConfirmed by Jawdah on request

Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Comparison

150 mm compared with the other cold room thicknesses

Jawdah's data sheet gives U 0.46, 0.31 and 0.23 W/m²·K for 50, 75 and 100 mm; each extra step of core thickness buys a smaller reduction in heat flow. For 150 and 200 mm, Jawdah confirms the thermal values with the quotation.

Confirm the 150 and 200 mm values in writing before the design is fixed.

Cold room wall panel thicknesses compared (Jawdah's data sheet)
Panel thicknessR-value (m²·K/W)U-value (W/m²·K)Listed on
50 mm2.170.46Jawdah's data sheet
75 mm3.260.31Jawdah's data sheet
100 mm4.350.23Jawdah's data sheet
150 mm (this page)Confirmed by Jawdah on requestConfirmed by Jawdah on requestListed by Jawdah
200 mmConfirmed by Jawdah on requestConfirmed by Jawdah on requestListed by Jawdah

Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.

Materials

Faces for a 150 mm cold room

Jawdah lists PPGI, aluminium, stainless steel and galvanised iron facings with polyester or PVDF coating, Cloud White as standard. Choose the internal face for the room's cleaning regime and hygiene audits, and the external face for the hall or outdoor exposure around it.

Key facts

  1. Jawdah lists a 150 mm PIR cold room wall panel in its cold room range.
  2. 150 mm cold room wall panel: R- and U-values confirmed by Jawdah with the quotation.
  3. Jawdah's cold room wall panel range covers 50, 75, 100, 150 and 200 mm.
  4. Availability of the 150 mm cold room panel is confirmed by Jawdah per order.
  5. The 100 mm cold room panel core has U 0.23 W/m²·K on Jawdah's data sheet.
  6. Jawdah does not publish cold room temperature ranges per thickness.

RFQ / BOQ checklist

  • Room internal dimensions and number of rooms
  • Required room set temperature
  • Surroundings: inside a conditioned hall, an unconditioned hall or outdoors
  • Refrigeration heat-load result or target wall U-value
  • Panel thickness: 150 mm
  • Internal face material and coating for the cleaning regime
  • External face material, coating and colour
  • Ceiling arrangement and floor detail
  • Door sizes, positions and penetrations
  • Project location and delivery schedule

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • Jawdah confirms the U-value and R-value of the 150 mm PIR core with the quotation.

  • Jawdah lists 150 mm in its cold room range. Confirm availability and values with Jawdah before ordering.

  • As general guidance, when a heat-load calculation shows that 100 mm leaves too much heat gain, for example for rooms with a large temperature difference or outdoor exposure.

  • The 100 mm panel has U 0.23 W/m²·K; Jawdah confirms the 150 mm value with the quotation, so the heat-load calculation can compare both.

  • Each extra step of core thickness buys a smaller reduction in heat flow. Jawdah confirms the 200 mm values with the quotation; whether it pays off depends on the room's heat-load calculation.

  • No. At this depth joints, the floor junction and penetrations account for a larger share of heat gain, so they need continuous sealing and insulated details.

  • No. Jawdah does not publish cold room temperature ranges per thickness; the choice is made per project.

Next step

Request 150 mm cold room wall panels

Send the room sizes, set temperature, surroundings and heat-load result. The Jawdah team will confirm 150 mm availability, the applicable data sheet and a quotation.