Cold Room Wall Panels · 150 mm
Cold Room Wall Sandwich Panel — 150 mm
The 150 mm cold room wall panel is a deep-core PIR panel in Jawdah's cold room range; Jawdah confirms its thermal values with the quotation.
- Thickness
- 150 mm
- R-value (core)
- Confirmed by Jawdah on request
- U-value (core)
- Confirmed by Jawdah on request
- Core
- Rigid PIR

Overview
Quick answer
Jawdah's 150 mm cold room wall panel is a PIR-core sandwich panel for rooms that need deep insulation. Jawdah lists this thickness and confirms its thermal values with the quotation, so confirm availability and values with Jawdah when ordering.
Overview
What the 150 mm cold room panel is
Jawdah lists the 150 mm thickness in its cold room range and confirms its thermal values with the quotation; availability is confirmed per order. See the cold room wall sandwich panel page for room design basics.
It is a cold room wall element with a 150 mm rigid PIR core between two metal facings, half again as deep as the 100 mm panel. The deeper core is there to cut heat gain into rooms where the temperature difference across the wall is large or the refrigeration load must be kept low.
Availability of this thickness is confirmed with each order.
Performance
Details for a 150 mm cold room
At this depth the panel itself lets little heat through, so joints, the floor and openings decide the result. As general practice for low-temperature rooms, insulate the floor or provide a thermal break at the base, seal every joint and corner continuously, sleeve penetrations, and coordinate doors, pressure relief and lighting with the panel layout. Trims come from the wall flashings range.
Applications
Where a 150 mm cold room wall typically fits
As general guidance, a 150 mm core is considered for rooms with a large temperature difference to their surroundings, such as frozen storage, or for rooms exposed to outdoor heat rather than sheltered in a hall. Jawdah does not publish set points per thickness, so the refrigeration heat-load calculation should show that 150 mm is needed.
If the calculation is met at 100 mm, the 100 mm panel has values on Jawdah's data sheet; if it asks for more, compare the 200 mm panel.
Choosing
Ordering 150 mm cold room panels
Ask Jawdah first to confirm that 150 mm is available and which data sheet applies, then send room sizes, set temperature, surroundings, heat-load result, faces, ceiling and floor details, doors and quantities.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
What Jawdah lists for 150 mm
Jawdah lists the cold room wall panel in 50, 75, 100, 150 and 200 mm. For 150 mm, Jawdah confirms the thermal values with the quotation.
- Thickness: 150 mm
- Core: rigid PIR
- R- and U-values: confirmed by Jawdah with the quotation
- Range: 50, 75, 100, 150 and 200 mm
- Availability: confirmed by Jawdah per order
Specifications
Thermal values of the 150 mm cold room panel
Jawdah confirms the R- and U-values of the 150 mm panel with the quotation. As for the thinner panels, the values cover the insulation core only and exclude surface resistances and thermal bridging.
| Panel thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 150 mm | Confirmed by Jawdah on request | Confirmed by Jawdah on request |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.
Comparison
150 mm compared with the other cold room thicknesses
Jawdah's data sheet gives U 0.46, 0.31 and 0.23 W/m²·K for 50, 75 and 100 mm; each extra step of core thickness buys a smaller reduction in heat flow. For 150 and 200 mm, Jawdah confirms the thermal values with the quotation.
Confirm the 150 and 200 mm values in writing before the design is fixed.
| Panel thickness | R-value (m²·K/W) | U-value (W/m²·K) | Listed on |
|---|---|---|---|
| 50 mm | 2.17 | 0.46 | Jawdah's data sheet |
| 75 mm | 3.26 | 0.31 | Jawdah's data sheet |
| 100 mm | 4.35 | 0.23 | Jawdah's data sheet |
| 150 mm (this page) | Confirmed by Jawdah on request | Confirmed by Jawdah on request | Listed by Jawdah |
| 200 mm | Confirmed by Jawdah on request | Confirmed by Jawdah on request | Listed by Jawdah |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.
Materials
Faces for a 150 mm cold room
Jawdah lists PPGI, aluminium, stainless steel and galvanised iron facings with polyester or PVDF coating, Cloud White as standard. Choose the internal face for the room's cleaning regime and hygiene audits, and the external face for the hall or outdoor exposure around it.

Key facts
- Jawdah lists a 150 mm PIR cold room wall panel in its cold room range.
- 150 mm cold room wall panel: R- and U-values confirmed by Jawdah with the quotation.
- Jawdah's cold room wall panel range covers 50, 75, 100, 150 and 200 mm.
- Availability of the 150 mm cold room panel is confirmed by Jawdah per order.
- The 100 mm cold room panel core has U 0.23 W/m²·K on Jawdah's data sheet.
- Jawdah does not publish cold room temperature ranges per thickness.
RFQ / BOQ checklist
- Room internal dimensions and number of rooms
- Required room set temperature
- Surroundings: inside a conditioned hall, an unconditioned hall or outdoors
- Refrigeration heat-load result or target wall U-value
- Panel thickness: 150 mm
- Internal face material and coating for the cleaning regime
- External face material, coating and colour
- Ceiling arrangement and floor detail
- Door sizes, positions and penetrations
- Project location and delivery schedule
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
Jawdah confirms the U-value and R-value of the 150 mm PIR core with the quotation.
Jawdah lists 150 mm in its cold room range. Confirm availability and values with Jawdah before ordering.
As general guidance, when a heat-load calculation shows that 100 mm leaves too much heat gain, for example for rooms with a large temperature difference or outdoor exposure.
The 100 mm panel has U 0.23 W/m²·K; Jawdah confirms the 150 mm value with the quotation, so the heat-load calculation can compare both.
Each extra step of core thickness buys a smaller reduction in heat flow. Jawdah confirms the 200 mm values with the quotation; whether it pays off depends on the room's heat-load calculation.
No. At this depth joints, the floor junction and penetrations account for a larger share of heat gain, so they need continuous sealing and insulated details.
No. Jawdah does not publish cold room temperature ranges per thickness; the choice is made per project.

Next step
Request 150 mm cold room wall panels
Send the room sizes, set temperature, surroundings and heat-load result. The Jawdah team will confirm 150 mm availability, the applicable data sheet and a quotation.




