Cold Room Wall Panels · 100 mm
Cold Room Wall Sandwich Panel — 100 mm
The 100 mm cold room wall panel sits in the middle of Jawdah's PIR cold room wall range, between the 75 mm panel and the deeper 150 and 200 mm panels.
- Thickness
- 100 mm
- R-value (core)
- 4.35 m²·K/W
- U-value (core)
- 0.23 W/m²·K
- Core
- Rigid PIR

Overview
Quick answer
Jawdah's 100 mm cold room wall panel is a PIR-core sandwich panel for refrigerated rooms. Jawdah's data sheet gives R 4.35 m²·K/W and U 0.23 W/m²·K for the core alone, half the heat flow of the 50 mm panel. For the deeper 150 and 200 mm panels, Jawdah confirms the thermal values with the quotation.
Overview
What the 100 mm cold room panel is
Jawdah's data sheet gives 100 mm an R-value of 4.35 m²·K/W and a U-value of 0.23 W/m²·K. Room-level design advice is on the cold room wall sandwich panel page.
A rigid PIR core of 100 mm sits between two metal facings, giving a wall element that limits heat gain, keeps air and vapour out of the foam and offers a cleanable face. Within the cold room range it is the last step before the deeper 150 and 200 mm panels.
For a refrigerated room, halving the U-value roughly halves the heat entering through that wall; the 100 mm panel does exactly that compared with 50 mm.
Performance
Details for a 100 mm cold room
The deeper the wall, the more of the remaining heat gain comes from details. Plan an insulated floor or a thermal break at the base, continuous sealing at every joint and corner, sealed sleeves at penetrations, and door frames coordinated with the panel layout. Use wall flashings and hygienic trims that leave no ledges for dirt.
Applications
Where a 100 mm cold room wall typically fits
As general guidance, a 100 mm core is considered where the room is kept well below its surroundings or the refrigeration load must stay low: chilled and frozen food stores, agricultural produce and date storage, pharmaceutical and medical storage, and rooms that stand in unconditioned halls.
Jawdah does not publish which thickness fits which set point. Where a calculation asks for more than 100 mm, compare the 150 mm and 200 mm panels, whose thermal values Jawdah confirms with the quotation; where less is enough, the 75 mm panel keeps the wall thinner.
Choosing
Ordering 100 mm cold room panels
Send room dimensions, set temperature, surroundings, heat-load result or target U-value, internal and external faces, ceiling arrangement, floor detail, door positions and quantities. Jawdah confirms the build-up, joints and sealing per project.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
Data-sheet facts for 100 mm
Jawdah lists the cold room wall panel in thicknesses from 50 to 200 mm, and its data sheet gives the 100 mm thermal values below.
- Thickness: 100 mm
- Core: rigid PIR
- R 4.35 m²·K/W; U 0.23 W/m²·K (core only)
- Calculated from λ = 0.023 W/m·K
- Recommended room temperatures: not published
Specifications
Thermal values of the 100 mm cold room panel
With λ = 0.023 W/m·K, the 100 mm core reaches R 4.35 m²·K/W, and its inverse gives U 0.23 W/m²·K: around 0.23 watts per square metre of core for each kelvin of difference between the room and its surroundings. These are calculated core values without surface resistances or thermal bridging.
| Panel thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 100 mm | 4.35 | 0.23 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.
Comparison
100 mm compared with the other cold room thicknesses
The 100 mm panel lets through half the heat of 50 mm (U 0.46 W/m²·K) and about a quarter less than 75 mm (U 0.31 W/m²·K). For the 150 and 200 mm panels, Jawdah confirms the thermal values with the quotation.
Confirm availability with Jawdah before designing around 150 or 200 mm.
| Panel thickness | R-value (m²·K/W) | U-value (W/m²·K) | Listed on |
|---|---|---|---|
| 50 mm | 2.17 | 0.46 | Jawdah's data sheet |
| 75 mm | 3.26 | 0.31 | Jawdah's data sheet |
| 100 mm (this page) | 4.35 | 0.23 | Jawdah's data sheet |
| 150 mm | Confirmed by Jawdah on request | Confirmed by Jawdah on request | Listed by Jawdah |
| 200 mm | Confirmed by Jawdah on request | Confirmed by Jawdah on request | Listed by Jawdah |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.
Materials
Faces for a 100 mm cold room
Facings available in the Jawdah wall range are PPGI, aluminium, stainless steel and galvanised iron, with polyester or PVDF coating and Cloud White as standard. In food, produce or pharmaceutical storage, choose the internal face for the cleaning chemicals and audit regime; stainless steel is the general choice for the strictest hygiene.

Key facts
- Jawdah lists its PIR cold room wall panel in 100 mm on its data sheet.
- 100 mm cold room wall panel: R 4.35 m²·K/W, U 0.23 W/m²·K, core only.
- 100 mm is the middle of the five cold room thicknesses: 50, 75, 100, 150 and 200 mm.
- The 100 mm cold room panel has half the core U-value of the 50 mm panel.
- For 150 and 200 mm cold room panels, Jawdah confirms thermal values with the quotation.
- Cold room condensation usually points to a thermal bridge or air leak at the floor, corners or penetrations.
RFQ / BOQ checklist
- Room internal dimensions and number of rooms
- Required room set temperature
- Surroundings: inside a conditioned hall, an unconditioned hall or outdoors
- Refrigeration heat-load result or target wall U-value
- Panel thickness: 100 mm
- Internal face material and coating for the cleaning regime
- External face material, coating and colour
- Ceiling arrangement and floor detail
- Door sizes, positions and penetrations
- Project location and delivery schedule
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
0.23 W/m²·K, with R 4.35 m²·K/W, on Jawdah's data sheet. The values cover the core only.
Jawdah does not publish a thickness per room temperature. As general guidance, rooms with large temperature differences use deeper cores; the heat-load calculation shows whether 100 mm or more is needed.
Jawdah lists the cold room wall panel from 50 to 200 mm. For 150 and 200 mm, Jawdah confirms the thermal values with the quotation.
Its U-value is half: 0.23 against 0.46 W/m²·K, so half as much heat passes through the core under the same conditions.
Jawdah lists both thicknesses. Confirm availability with Jawdah before designing around them; their thermal values are confirmed with the quotation.
Usually at thermal bridges or air leaks: the floor junction, corners and penetrations. Continuous sealing and insulated base details prevent it.
Ask for the applicable cold room data sheet, the System Catalogue and the Installation Manual, which Jawdah provides in hard copy, through the RFQ.

Next step
Request 100 mm cold room wall panels
Send the room sizes, set temperature, surroundings and heat-load result. The Jawdah team will confirm the 100 mm build-up, details and a project quotation.