Cold Room Wall Panels · 50 mm
Cold Room Wall Sandwich Panel — 50 mm
The 50 mm cold room wall panel is the thinnest core in Jawdah's PIR cold room wall range and the first of its five listed thicknesses.
- Thickness
- 50 mm
- R-value (core)
- 2.17 m²·K/W
- U-value (core)
- 0.46 W/m²·K
- Core
- Rigid PIR

Overview
Quick answer
Jawdah's 50 mm cold room wall panel is a PIR-core sandwich panel for temperature-controlled rooms. Jawdah's data sheet gives R 2.17 m²·K/W and U 0.46 W/m²·K for the core alone. As general guidance, the thinnest core suits rooms held only a little below the surrounding temperature, and a refrigeration heat-load calculation should confirm it.
Overview
What the 50 mm cold room panel is
Jawdah's data sheet lists 50 mm with an R-value of 2.17 m²·K/W and a U-value of 0.46 W/m²·K. Cold room design basics are on the cold room wall sandwich panel page; this page covers the 50 mm thickness.
It is an insulated wall element made of a rigid PIR core between two metal facings, used to build the walls of refrigerated and conditioned rooms. The core does the thermal work, the skins block air and moisture, and the factory-made edges let the room be assembled quickly inside a hall or as a stand-alone enclosure.
At 50 mm the panel has the least insulation of the cold room thicknesses Jawdah lists, so it lets the most heat into the room per square metre. That makes the room's set point, and the temperature around it, the deciding factors.
Performance
Details that matter at 50 mm
With a thin core, heat that bypasses the panel weighs more heavily on the result. Seal every joint continuously, treat the wall-to-floor junction as a thermal bridge, and use sealed sleeves for pipes and cables. Corner and base trims come from the wall flashings range.
Applications
Where a 50 mm cold room wall typically fits
Jawdah does not publish a temperature range for each thickness. As general guidance, the thinnest core is considered for rooms held close to the surrounding temperature, such as conditioned stores, anterooms and partitions between two rooms at similar temperatures, or where an air-conditioned hall already shelters the room.
Rooms with a larger temperature difference usually need a deeper core: compare the 75 mm and 100 mm cold room panels before ordering.
Choosing
Ordering 50 mm cold room panels
Send the room dimensions, set temperature, the surrounding conditions, the heat-load result or target U-value, internal and external facings, door positions and quantities. Jawdah confirms the panel build-up and the joint and sealing details per project.
Technical
Closer look
Detailed product imagery is being prepared.
In preparationJawdah data
What Jawdah's data sheets state for 50 mm
Jawdah lists the cold room wall panel in 50, 75, 100, 150 and 200 mm. Its data sheet gives 50 mm the thermal row below.
- Thickness: 50 mm, on Jawdah's data sheet
- Core: rigid polyisocyanurate (PIR)
- R 2.17 m²·K/W; U 0.46 W/m²·K (core only)
- Basis: λ = 0.023 W/m·K, calculated
- Temperature range per thickness: not published
Specifications
Thermal values of the 50 mm cold room panel
R equals the 50 mm core depth divided by λ = 0.023 W/m·K, giving 2.17 m²·K/W; the U-value of 0.46 W/m²·K is its inverse. For a cold room this means roughly 0.46 watts of heat entering through each square metre of core for every kelvin between the room and its surroundings. Surface resistances and thermal bridging are excluded.
| Panel thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 50 mm | 2.17 | 0.46 |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.
Comparison
50 mm against the other cold room thicknesses
The cold room range runs from 50 to 200 mm. Each step lowers the U-value, but the gains shrink as the core grows: the jump from 50 to 75 mm saves more heat per square metre than any later step.
So for a refrigerated room it is worth checking whether a deeper wall cuts the refrigeration load enough to justify the extra depth and cost, before 50 mm is fixed in the design.
| Panel thickness | R-value (m²·K/W) | U-value (W/m²·K) |
|---|---|---|
| 50 mm (this page) | 2.17 | 0.46 |
| 75 mm | 3.26 | 0.31 |
| 100 mm | 4.35 | 0.23 |
| 150 mm | Confirmed by Jawdah with the quotation | Confirmed by Jawdah with the quotation |
| 200 mm | Confirmed by Jawdah with the quotation | Confirmed by Jawdah with the quotation |
Thermal values refer to the insulation core only and exclude surface resistances and thermal bridging.
Materials
Facings for a 50 mm cold room wall
Jawdah facings are PPGI, aluminium, stainless steel and galvanised iron, with polyester or PVDF coating and Cloud White as standard. As general practice, white pre-painted steel is common inside general food stores, while stainless steel is preferred where strong cleaning chemicals or strict hygiene audits apply.

Key facts
- Jawdah lists its PIR cold room wall panel in 50 mm on its data sheet.
- 50 mm cold room wall panel: R 2.17 m²·K/W and U 0.46 W/m²·K, core only.
- 50 mm is the thinnest of the cold room thicknesses 50, 75, 100, 150 and 200 mm.
- Jawdah does not publish cold room temperature ranges per thickness; selection follows a heat-load calculation.
- Cold room thermal values exclude surface resistances and thermal bridging.
- Stainless steel is among the facings Jawdah offers for hygiene-sensitive cold rooms.
RFQ / BOQ checklist
- Room internal dimensions and number of rooms
- Required room set temperature
- Surroundings: inside a conditioned hall, an unconditioned hall or outdoors
- Refrigeration heat-load result or target wall U-value
- Panel thickness: 50 mm
- Internal face material and coating for the cleaning regime
- External face material, coating and colour
- Ceiling arrangement and floor detail
- Door sizes, positions and penetrations
- Project location and delivery schedule
Resources
Further chapters in preparation
Technical resources
Technical documentation is being prepared for this product.
Projects using this product
Project references are being prepared.
Compatible systems
Information on compatible systems for this product is being prepared.
Our technical team can share the current information on request.Ask the technical team
FAQ
Frequently asked questions
0.46 W/m²·K, with R 2.17 m²·K/W, on Jawdah's data sheet. The values describe the PIR core only.
Jawdah does not publish a thickness per room temperature. As general guidance, freezer rooms have large temperature differences and normally use deeper cores; a heat-load calculation decides.
As general guidance, rooms held close to the surrounding temperature, anterooms and internal partitions between rooms at similar temperatures.
The 75 mm panel has U 0.31 W/m²·K against 0.46 W/m²·K, roughly a third less heat flow through the core.
Yes. Jawdah's data sheet lists 50 mm with the thermal values shown on this page. Availability is confirmed with each order.
White pre-painted steel is common for general food stores; stainless steel is preferred where aggressive cleaning or strict hygiene audits apply.
No. They are core-only values without surface resistances or thermal bridging, including at the floor junction, which needs its own detail.