Jawdah Industrial Co. Ltd.

Roof Flashings · RF-101

RF-101 Eave Gutter for Sandwich Panel Roofs

RF-101 Eave Gutter is the coded Jawdah roof flashing that runs along the low edge of a sandwich panel roof and collects the water draining from the panel troughs and carries it to the down spouts.

Code
RF-101
Position
Low roof edge
Sized by
Draining roof area and outlets
Dimensions
Confirmed per project
RF-101 Eave Gutter, 3D render of the folded steel flashing profile for sandwich panel roofs

Overview

Quick answer

RF-101 Eave Gutter is the formed metal gutter fixed along the eave of a sandwich panel roof. The roof panels overhang into it, water from the high-rib troughs drops in, and outlets connect it to down spouts. Its size depends on the roof area draining to it and the outlet spacing, so Jawdah confirms the RF-101 profile per project.

Overview

The eave gutter on a panel roof

Everything that falls on a roof slope ends at the eave, so the eave gutter carries the whole runoff of that slope.

RF-101 opens the Jawdah Roof Flashings range. Its girth, depth, gauge, material and lengths are not published, so this page explains where RF-101 sits, how it works with the roof panels and outlets, and what Jawdah needs to confirm it.

On a Jawdah roof, the high-rib panel channels rain down its troughs toward the eave. At the low edge the panel stops, and the water needs somewhere to go that is not the face of the wall below. RF-101 Eave Gutter is that place: a formed channel running the length of the eave, under the panel ends.

The panels normally overhang the gutter so water drops into it rather than running back along the panel underside. Outlets in the gutter base lead to Down Spout pipes and, where the pipe changes direction, an Elbow.

The eave gutter is the most capacity-sensitive item in the roof flashing set. A ridge cap only has to shed water; an eave gutter has to hold and carry the runoff of a whole slope. That is why RF-101 is sized per project from the roof plan rather than taken from a stock list.

RF-101 Eave Gutter

How it works

How the gutter, panel end and outlets work together

As general guidance, the gutter is set to a slight fall toward its outlets so water does not stand in it. The rib voids at the panel ends are closed with a profile filler, such as the coded RF-107 Foam Closure Trim, so wind cannot drive rain or dust up under the panel. The back of the gutter is lapped under the panel end or an eave flashing, never in front of it.

Types

RF-101 among the Jawdah roof flashings

Two Jawdah roof flashings carry water rather than just shedding it. The table separates RF-101 from its siblings.

Jawdah roof flashing codes by position (general guidance)
CodeItemPositionWater role
RF-101Eave GutterLow roof edgeCollects runoff of one slope
RF-102Valley GutterInternal junction of two slopesCollects runoff of two slopes
RF-103External Ridge CapRoof apex, outsideSheds water to both slopes
RF-104Internal Ridge CapRoof apex, room sideFinishes the inner face
RF-105Gable TrimSloping side edgeCloses the verge
RF-106Eave TrimLow roof edgeCloses the eave edge
RF-107Foam Closure TrimUnder caps and at eavesSeals the rib voids

Performance

Sizing information Jawdah needs

Gutter size follows the roof area that drains to it, the roof slope, the number and position of outlets and the local rainfall design value set by the project engineer. Give the roof plan with each slope's length and width, the planned outlet positions and the design intensity if it is specified, and Jawdah confirms the RF-101 section. State whether the roof uses 3-Rib Roof Panels or 5-rib panels so the eave filler can follow the rib shape.

Maintenance

Keeping an eave gutter working

In Saudi conditions the main enemy of an eave gutter is sand rather than leaves. Wind-blown sand settles in the gutter and outlets during the dry months and then blocks them in the first heavy rain. Inspect and clear gutters and outlets before the rainy season and after dust storms, and check laps and stop ends for aged sealant.

Applications

Eave gutter mistakes

Overflowing eave gutters usually trace back to design, not to the gutter itself.

  • Gutter sized by habit instead of by the slope draining to it
  • Too few outlets on long eaves
  • Gutter set level or falling away from the outlet
  • Panel ends stopping short of the gutter
  • Rib voids left open above the gutter

Choosing

RF-101 or RF-106?

Both codes sit at the low edge of the roof. Use RF-101 where the eave must collect water and lead it to down spouts. Use RF-106 Eave Trim to close and finish the eave edge, including where water is allowed to drip off freely. Many roofs need both, and both are quoted with the Roof Flashings package.

Technical

Closer look

Approved photography of the product and its finish.
RF-101 Eave Gutter section drawing
RF-101 Eave Gutter, 3D render of the folded steel flashing profile for sandwich panel roofs
RF-101 Eave Gutter flashing profile for sandwich panel roofs

Specifications

RF-101 data status

No technical data sheet covers Jawdah flashings, so the RF-101 values below are confirmed in the quotation.

RF-101 Eave Gutter data status
PropertyValue
Code and nameRF-101 Eave Gutter
RangeRoof Flashings
Girth, width and depthNot specified in the supplied data sheet
Material and thicknessNot specified in the supplied data sheet
Outlets and stop endsConfirmed per project

Key facts

  1. RF-101 Eave Gutter is a coded item in the Jawdah Roof Flashings range.
  2. RF-101 runs along the low edge of a sandwich panel roof and collects runoff from the panel troughs.
  3. Eave gutter size depends on the draining roof area, slope and outlets, so Jawdah confirms it per project.
  4. Down Spout and Elbow in the Jawdah Accessories range connect to the gutter outlets.
  5. RF-102 Valley Gutter collects water from two slopes; RF-101 from one.

RFQ / BOQ checklist

  • Roof plan with every eave marked RF-101 and its length
  • Slope length and width draining to each eave
  • Roof pitch
  • Outlet positions and down spout routes
  • Rainfall design value, if specified by the engineer
  • Roof panel variant: 3-rib or 5-rib
  • Colour and material to match the roof
  • Down spouts, elbows and closures needed with the gutter

Resources

Further chapters in preparation

In preparation
  • Technical resources

    Technical documentation is being prepared for this product.

  • Projects using this product

    Project references are being prepared.

  • Compatible systems

    Information on compatible systems for this product is being prepared.

Our technical team can share the current information on request.Ask the technical team

FAQ

Frequently asked questions

  • A coded Jawdah roof flashing: the gutter fixed along the low edge of a sandwich panel roof that collects panel runoff and leads it to down spouts.

  • From the roof area draining to it, the slope, the outlet positions and the project's rainfall design value. Jawdah confirms the section per project.

  • An eave gutter collects water from one slope at the roof edge. A valley gutter, RF-102, sits where two slopes meet and collects water from both.

  • Down Spout and Elbow are listed in the Jawdah Accessories range. Include them in the same RFQ as RF-101.

  • Wind-blown sand collects in gutters and outlets during dry months, so they should be cleared before the rainy season and after dust storms.

  • No. Girth, depth, material, thickness and lengths are confirmed by Jawdah for each roof.

Next step

Get RF-101 sized for your roof

Send the roof plan with eave lengths, slopes and outlet positions. The Jawdah team will confirm the RF-101 gutter, outlets and accessories with the roof panels.